MSD
TM
Series
© Copyright 2018 Fluid Equipment Development Company | www.fedco-usa.com
-
39
-
Pump Assembly Continued
FEELER GAGE
Figure 69 - Measuring Motor Adapter Side Gap
12. Using feeler gauges, re-measure any gap
between the motor adapter and the motor
on both sides of the motor adapter.
NOTES:
In some instances, there may be no
gap between the motor and motor adapter.
NOTES:
These values should be identical with
the “C” & “D” values found in the
Start Up Re
-
cord
section of this manual.
11. Tighten all precision leveling feet top nuts
to torque specs specified in the
Fastener
Torque Specifications
section of this manu-
al.
Figure 68 -
Precision Leveling Foot Top Nuts
Figure 67 -
Intermediate Leveling Foot
Adjustment
10. Rotate the adjustment nuts on the inter-
mediate leveling feet until they contact the
bottom of the stage brackets.