Il presente documento è di proprietà della FEAM La sua riproduzione in qualsiasi formato, integrale o parziale, deve essere preventivamente autorizzata dalla FEAM  

The present document is property of FEAM. Its copyright in any format, whole or partial, must be before authorized by FEAM  

IU-15-278_Rev1.doc

 

 

 

 

 

 

 

 

 

(1) 

marchio, nome ed indirizzo del fabbricante 

(2) 

designazione del tipo di apparecchiatura data dal fabbricante 

(3) 

anno di costruzione e nr. matricola 

(4) 

campo temperatura ambiente 

(5) 

caratteristiche elettriche nominali 

(6) 

avvertenze usate per tutti i tipi di custodia 

(7) 

simbolo grafico della marcatura CE di conformità 

(8) 

marchio distintivo comunitario specifico della protezione contro le esplosioni 

(9) 

marcatura ATEX 
II: 

gruppo di apparecchi - apparecchiatura idonea ad essere installa in 
luoghi di superficie 

3G:  categoria – apparecchiatura idonea ad essere installata in luoghi in cui, 

durante le normali attività, vi è scarsa probabilità che si manifestino 
atmosfere esplosive dovute a gas, vapori o nebbie (zona 2); idonea 
ad essere istallata in zona 2. 

3D:   categoria – apparecchiatura idonea ad essere installata in luoghi in cui, 

durante le normali attività, vi è scarsa probabilità che si manifestino 
atmosfere esplosive dovute a miscele di aria e polveri combustibili 
(zona 22); idonea ad essere istallata in zona 22. 

(10) 

marcatura IECEx – modo di protezione 
Ex: protezioni 

contro le esplosioni. 

nR: 

modo di protezione “n” – costruzioni elettriche a respirazione limitata. 

IIC: 

apparecchiatura idonea ad essere installa in luoghi di superficie per 
tutti i tipi di gas combustibili. 

T3/T2 : classe di temperatura. 
Gc:      Apparecchiatura per l’utilizzo in atmosfere esplosive per la presenza 

 di  gas, con un livello di protezione ‘aumentato’, che non è  
una sorgente di accensione durante il funzionamento normale e  
che presenta alcune misure di protezione addizionali per assicurare 
che rimanga una sorgente di accensione non attiva in caso di eventi 
attesi con regolarità. 

tc: 

modo di protezione mediante custodia, (per EPL Db). 

Dc:      Apparecchiatura per atmosfere esplosive per la presenza di polveri, 

con un livello di protezione ‘aumentato’, che non costituisce una 
sorgente di innesco durante il funzionamento normale e che può 
avere protezioni addizionali per assicurare che rimanga inattiva come 
sorgente di innesco nel caso di guasti regolari ed attesi. 

T200 °C  temperatura massima superficiale 
T300°C   temperatura massima superficiale 

 

(1) 

brand, name and address of the manufacturer 

(2) 

equipment type designation given by manufacturer 

(3) 

year of construction and serial number 

(4) 

ambient temperature range 

(5) 

nominal electrical characteristic 

(6) 

warning used for all types of enclosure 

(7) 

graphic symbol of conformity CE marking 

(8) 

distinctive community mark specific of explosion protection 

(9) 

ATEX marking 
II: 

group of apparatus - equipment suitable to be installed in surface 
places 

3G:  category – equipment suitable to be installed in places in which, 

during the normal activities, explosive atmosphere caused by gases, 
vapours, mists (G) are scarce possibility to occur (zone 2); suitable to 
be installed in zone 2. 

3D:  category – equipment suitable to be installed in places in which, during 

the normal activities, explosive atmosphere caused by mixture of air 
and combustible dust scarce possibility to occur (zone 22); suitable to 
be installed in zone 22. 

(10)

IECEx marking – type of protection 
Ex: protection 

against explosion. 

nR: 

type of protection “n” – restricted breathing electrical device. 

IIC: 

equipment suitable to be installed in surface places for all types of 
combustible gas. 

T3/T2 : temperature class. 
Gc:       Equipment for explosive gas atmospheres, having a “enhanced” 

level of protection, which is not source of igniton in normal operation 
and which may have some additional protection to ensure that it 
remains inactive as an ignition source in the case of regular 
expected occurrences. 

 
tc:   

protection by enclosures, (for EPL Db). 

Dc:       Equipment for explosive dust atmospheres, having a “enhanced” 

level of protection, which is not a source of ignition in normal 
operation and which may have some additional protection to ensure 
that it remains inactive as an ignition source in the case of regular 
expected occurrences. 

T200 °C  maximum surface température 
T300 °C maximum surface température 

 

Содержание SFDN 125 QT

Страница 1: ...o or re e p pe er r l la am mp pa ad de e a a s sc ca ar ri ic ca a t ti ip po o S SF FD DN N F Fl lo oo od dl li ig gh ht t f fo or r d di is sc ch ha ar rg ge e l la am mp ps s t ty yp pe e S SF FD...

Страница 2: ...and type designation 5 2 2 Nome e indirizzo del produttore 6 2 2 Producer name and address 6 3 SPECIFICA DEL PRODOTTO 6 3 SPECIFICATION OF THE PRODUCT 6 3 1 Funzioni generali e gamma di applicazioni...

Страница 3: ...formazioni contenute nel presente manuale sono indirizzate ai seguenti soggetti addetti al trasporto movimentazione disimballo addetti alla preparazione degli impianti e del sito di installazione inst...

Страница 4: ...esto manuale In accordo alla Direttiva 1999 43 CE del Parlamento Europeo e del Consiglio la durata della garanzia di due anni dalla data di consegna L uso di ricambi non originali FEAM fa decadere la...

Страница 5: ...hiena In case of not respect of the instructions would be the risk of muscle skeletal lesions to the back 2 IDENTIFICAZIONE 2 IDENTIFICATION 2 1 Marca del prodotto e designazione del tipo 2 1 Product...

Страница 6: ...stallatore e l utilizzatore devono conoscere i rischi associati alla corrente elettrica e alle caratteristiche chimiche dei gas e o vapori presenti in zona con pericolo di esplosione Entrambi devono e...

Страница 7: ...70 SFDN 250 QT 250 W 11 40 SFDN 400 QT 400 W 12 10 3 3 Dati tecnici 3 3 Technical data materiali materials Corpo coperchio Lega di alluminio GA1 Si 13 KSi13 UNI EN 1706 1999 Il contenuto di magnesio...

Страница 8: ...nt document is property of FEAM Its copyright in any format whole or partial must be before authorized by FEAM IU 15 278_Rev1 doc Un 110 277Vac fn 50 60 Hz Pmax 400W Un 110 277Vac fn 50 60 Hz Pmax 400...

Страница 9: ...regolarit tc modo di protezione mediante custodia per EPL Db Dc Apparecchiatura per atmosfere esplosive per la presenza di polveri con un livello di protezione aumentato che non costituisce una sorge...

Страница 10: ...edamp non conductive dust 11 Identification of Notified Body that have issued the ATEX and IECEx certificate and its relative number see declaration of conformity 12 Other markings Surface exposed to...

Страница 11: ...s of electrical railway networks great systems of welding electrical systems with high currents and radio frequencies etc it is right to take adequate precautions to avoid consequences Come regola gen...

Страница 12: ...sulla parte superiore dell apparecchio e svitare la vite di sicurezza applicata al coperchio Per la chiusura eseguire la procedura al contrario The floodlight shall be installed according IEC EN60079...

Страница 13: ...e la griglia frangiluce o la visiera di controllo utilizzare le viti autofilettanti fornite nel kit di installazione e fissarle come da figura Pic 5 To install the protection grid optional the screen...

Страница 14: ...orta di prova The cable entry device or the compartment used for termination must maintain the IP66 rating The lighting fixture is provided with the test port 5 MANUTENZIONE E PULIZIA 5 MAINTAINING AN...

Отзывы: