49
INSTALLATION
Thanks to the support of the VHA-2F 406 flybar attached to the 2
VHA-f 406 flybars, it is possible to set up a maximum of 12 modules in
a vertical array.
To connect the modules in vertical array, proceed as follows:
STEP 1
:
Position the VHA 112SND and VHA 406ND models as shown in the
figure by following the instructions on the label of the VHA-2F 406 flybar
and hook it to the VHA-f 406 flybars.
STEP 2
:
Insert the pin of the VHA-2F 406 flybar in position 1.
STEP 3
:
Continue assembling the modules one at a time alternating left and right.
STEP 4
:
Remove the pin of the VHA-2F 406 flybar from position 1, bring the mo
-
dules closer and snap them by inserting the pin in position 2.
3 X VHA 112SND
3 X VHA 406ND
6 X VHA 112SND
6 X VHA 406ND