background image

31

NETWORKING

NETWORKING OF SPEAKERS

All the speakers are equipped with a dual Ethernet port for connection 
to INFINITO MANAGEMENT SOFTWARE and a high-brightness front 
BLUE LED that allows you to physically identify the speaker when 
connected to the network and remotely controlled.
With the WINK function present on the INFINITO software, the LED 

flashes  allowing  the  association  between  the  virtual  device  in  the  PC 

workspace and the physical device.
There are 3 ways to connect to the network:
1. 

Star connection: it is possible to connect each speaker individually 

to the network by connecting the NET IN port directly to the dedicated 
switch. This type of connection is the simplest from the point of view of 

the  complexity  of  the  network  itself,  as  it  involves  the  least  number  of 

HOPS (switch jumps that a packet must make from the PC to the target 
device). This type requires a large number of network ports on switches 

and also very long wiring to reach the farthest devices (for example, the 

speakers at the end of a line array). From a safety point of view, a faulty 
network cable results in a loss of control on only one device
2. 

Daisy Chain connection: it is possible to connect a whole series of 

speakers close together (e.g. Line array) to a single switch network port, 
using both available NET IN and NET OUT connections. Simply connect 

the switch port to the first speaker through the NET IN port, then wire 

the NET OUT with the NET IN of the second speaker, and so on to the last 

in the series. This type of connection simplifies the physical operation of 

wiring, resulting in being able to use shorter cables (similar to the set-up 
for the analog signal link), but complicates the structure of the network 
and increases the number of hops (and therefore the arrival time) of 
network packets especially intended for devices at the bottom of the 
chain. Any interruption of a network cable results in the loss of control 
on all devices located downstream of the breakage
3. 

Mixed connection: it is possible to use a mixed structure, dividing 

each  cluster  into  subgroups  of  devices.  The  first  device  in  each  group 

is connected via NET IN to the switch, then using the daisy chain 
structure the other elements are connected. In this case, an intermediate 

complexity  network  is  obtained  both  from  the  physical  point  of  view 

of the wiring and from that of the operation of the network itself. The 
interruption of a network cable causes the loss of a small number of 
devices, depending on how many devices each group contains and the 
level at which the breakage occurred within the group. 

In  the  case  of  a  large  number  of  devices  (for  example,  very  large  line 
arrays) it is advisable to use a mixed connection, dedicating a switch for 

each line array and dividing it into groups of up to 8 devices, connected to 
each other in a daisy chain.
Each device is equipped with a hardware bypass device of the network 
that, in the event of a serious malfunction that involves the shutdown 
of the internal logic, short-circuits the NET IN and NET OUT ports; in 
this way, all the devices located downstream of the breakage will still be 
controllable through INFINITY. 

The system is able to compensate for 

the breakage of 3 consecutive devices within each single daisy chain.

In order to ensure the correct operation of the system it is advisable to 
use cables of category CAT5e or higher.

SN / SND UPGRADE PROCEDURE

Optional DANTE module installation (upgrade from SN  / SND version)
• 

Remove the rear panel

• 

Refer to the figure to locate the position of the card and the 
correct orientation

• 

Lift the flat cable and gently press the card in alignment with the 
connectors so that the PCB touches the screw columns

• 

Screw in the two fixing screws supplied

• 

Reposition the rear panel

• 

When switched on, the system detects the new “SND” version 
which entails additional functions in the menu (related to 
DANTE). By connecting the device to the network, the INFINITO 
MANAGEMENT SUITE software detects the “SND” model

Содержание HORIZON VHA 118.2SA

Страница 1: ...VHA 118SND 118SN 118 2SA 118S CODE 45737 IT MANUALE D USO EN OPERATING MANUAL Processed Active Subwoofer ...

Страница 2: ......

Страница 3: ...ca SpA 62019 Recanati Italy www fbt it info fbt it VHA 118SND 118SN 118 2SA 118S 3 INFORMAZIONI GENERALI 3 AVVERTENZE 4 CARATTERISTICHE GENERALI 5 Descrizione 5 Specifiche 5 DIMENSIONI 6 CONTROLLI FUNZIONI 7 VHA 118SND 118SN 7 VHA 118S 7 VHA 118 2SA 8 ALIMENTAZIONE 9 Alimentazione 220V 240V 9 Alimentazione 120V 9 INGRESSI USCITE 10 Connessione XLR 10 Connessione Ethernet 10 Speakon 10 COLLEGAMENTO...

Страница 4: ... esposizione alla pioggia o all umidità anomalie di funzionamento o cadute dell apparecchio ATTENZIONE RISCHIO DI SHOCK ELETTRICO NON APRIRE PER EVITARE IL RISCHIO DI SHOCK ELETTRICO NON APRIRE IL COPERCHIO NON USARE UTENSILI MECCANICI ALL INTERNO CONTATTARE UN CENTRO DI ASSISTENZA QUALIFICATO PER EVITARE IL RISCHIO DI INCENDIO O DI SHOCK ELETTRICO NON ESPORRE L APPARECCHIATURA ALLA PIOGGIA O ALL ...

Страница 5: ...nte in un nuovo livello di prestazioni e semplicità Si tratta di una piattaforma software totalmente sviluppata internamente dal team di ricerca e sviluppo di FBT che offre monitoraggio in tempo reale dei sensori interni e dello stato dei dispositivi collegati Vu meter IN OUT controlli di tutti i parametri gestione dei gruppi lettura degli avvisi Il modulo è contenuto in uno chassis di alluminio c...

Страница 6: ...CARATTERISTICHE 700mm 720mm 606mm 611mm 711mm 6 DIMENSIONI VHA 118SND 118SN 2SA S ...

Страница 7: ...nnettori etherCON RJ45 utilizzata per l uscita daisy chain di rete ethernet del controllo e monitoraggio remoto INFINITO SOFTWARE MANAGEMENT SUITE 5 Volume digitale generale per il controllo del livello dei segnali miscelati Premere per entrare nel menu del DSP e ruotare la manopola per la scelta e la selezione dei parametri 6 Visualizzazione menu e impostazioni del DSP 7 CONTROLLI FUNZIONI 5 6 VH...

Страница 8: ...urpose adatto quindi alla maggior parte delle applicazioni DEEP questo preset estende ed enfatizza la gamma bassa del subwoofer per un suono molto profondo e morbido adatto in applicazioni di alta qualità e media energia quali musica acustica jazz ecc PUNCH il suono del sub diventa più asciutto meno estensione in bassa frequenza ma più energia concentrata in gamma 80 120Hz adatto al rock e ad appl...

Страница 9: ...i alimentazione AWG12 SJT vW1 con una spina di corrente nominale superiore o uguale a 30A IL CAVO E LA SPINA DEVONO ESSERE CERTIFICATI UL O CSA N max moduli per linea diconnessione 2 x VHA 118SND con cavo in dotazione 3 x VHA 118SND con cavo AWG12 SJT W1 AC LOOP OUTPUT AC INPUT Power consumption 650 W Input Range 100 240 V 50 60 Hz 50 60 Hz 3 A 220 240 V 50 60 Hz 6 5 A 100 120 V 13 A 220 240 V 13 ...

Страница 10: ...stema ad 1 via necessità cioè di essere pilotato da un canale di amplificazione opportunamente processato con parametri DSP forniti da FBT Un uso improprio del sistema con settaggi DSP non corretti può compromettere l affidabilità dei trasduttori ed esibire una performance acustica non ottimale Internamente non è presente un crossover passivo gli altoparlanti sono collegati direttamente ai connett...

Страница 11: ...izzando entrambe le connessioni NET IN e NET OUT disponibili È sufficiente connettere la porta dello switch al primo diffusore attraverso la porta NET IN quindi cablare la NET OUT con la NET IN del secondo diffusore e così via fino all ultimo della serie Questo tipo di connessione semplifica l operazione fisica di cablaggio permettendo di utilizzare cavi più corti analogamente a quanto viene fatto...

Страница 12: ...e sia disconnessa o il software sia in stato OFFLINE in tale caso il display locale mostra la scritta Switch to local control NO YES Selezionando YES si attiva la procedura di sblocco sul display appare Push and hold for 3 seconds ed in seguito alla pressione prolungata il display torna attivo riabilitando i controlli locali Una volta effettuato il passaggio alla modalità di controllo locale manua...

Страница 13: ...del display mostra le informazioni essenziali del diffusore ANALOG DELAY INV VHA112No Omni 0 dB PEAK FAN TEMP LIMIT LIMIT 1 2 5 3 4 6 7 8 9 10 INDICATORI DI GUASTO In caso di malfunzionamento il display fornisce indicazione della possibile causa discernendo tra cause termiche ex il malfunzionamento della ventola impedisce all amplificatore di dissipare il calore in eccesso portando il sistema a su...

Страница 14: ...Select SNAP ENABLE ON THRES 45 dB EXIT SUB ON TYPE MANUAL SIGNAL EXT VOLUME OFF EXIT LOCK SCREEN CONTRAST DISPLAY OFF ROTATION FACTORY RESET INFO EXIT muse 118 MENÚ PRINCIPALE EXIT CONFIG PRESET SOUND PRESET Dalla schermata HOME premendo la manopola si accede al menu dove vengono elencate tutte le funzioni controllabili ruotando la manopola si scorre l elenco in senso verticale Cliccando su una vo...

Страница 15: ...nd hold for 3 seconds VHA112No Omni ANALOG Temp Protection VHA112No Omni Yes No THRES 45 dB EXIT SUB ON TYPE MANUAL SIGNAL EXT VOLUME OFF EXIT CONFIG PRST SELECT MENÚ PRINCIPALE EXIT CONFIG PRESET SOUND PRESET PHASE DELAY IN ROUTING OUT ROUTING 1 NOISE GATE AUTO ST BY DANTE SENSORS TEST MEMORY LOCK SCREEN 2 3 VHA112 No Omni SOUND PRST SELECT Original SOUND PRST SELECT Hung DELAY VALUE 0 00 m 0 00 ...

Страница 16: ...TRAST LEVEL 5 DISPLAY OFF TIME OUT 60 s ROTATION ANGLE 90 SERVICE SENSORS TEST EXIT DANTE RATE 48 kHz LATENCY 1 ms PCM 24 bit STATUS NO AUDIO S 26 C 36 C 0 RST n to INFO VHA 118SND FW 1 0 0000 TEST Ú SERVICE Ú MEMORY Y O MEM RECALL INFINITO DEFAULT SNAP 1 SNAP 2 SNAP 3 SNAP 4 EXIT MEM SAVE SNAP 1 SNAP 2 SNAP 3 SNAP 4 EXIT Select SNAP MEM DELETE SNAP 1 SNAP 2 SNAP 3 SNAP 4 EXIT Select SNAP Push but...

Страница 17: ...00 x 112 5mm Acciaio max 6 moduli Acciaio max 3 moduli VHA T 118 VHA RC 118 VHA C 118S VHA CH 118S MS F 210 VHA B 406 VHA B 406 SUPPORTO FISSAGGIOMS F 210 È possibile effettuare una configurazione in ground stack utilizzando moduli FBT MUSE 210LND 210LN 17 ACCESSORI MS J 210 FISSAGGIO SUB Acciaio KBW 10045 RUOTE CON FRENO ...

Страница 18: ...uperficie piana e non sdrucciolevole in caso di superficie di appoggio che presenti una minima inclinazione è obbligatorio fissare opportunamente l installazione con adeguati mezzi meccanici o cinghie Predisposizione per montaggio accessorio MS F 210 modello MUSE 210LND LN sopra il sub Predisposizione per montaggio accessorio VHA B 406 modelli HORIZON VHA 406ND N e VHA 112SND SN sopra il sub Predi...

Страница 19: ...o acustico Per eseguire una configurazione cardioide è necessario impiegare un sub puntato posteriormente ogni due sub puntati frontalmente Gran parte dell energia prodotta dal sub posteriore viene utilizzata per cancellare l energia prodotta dagli altri due sub frontali quindi l SPL massimo complessivo dei tre sub nella zona frontale sarà di circa 1dB rispetto ad una configurazione classica non c...

Страница 20: ...CH permette di avere un basso veloce e di grande impatto sui 60 90Hz particolarmente apprezzato in live CONFIG PRST SELECT 2 Way CONFIG PRST SELECT 3 Way PRESET SELECT 2 Way PRESET SELECT 3 Way HPF STATE ON SOUND PRST SELECT Low Extension ON CONFIG PRST SELECT VHA 112 Yes CONFIG PRST SELECT VHA 112 No 1Sub 1 Top 1Sub 2 Top 1Sub 3 Top 2Sub 1 Top 1 Box 2 Box 3 4 Box 5 6 Box 1 Box 2 Box 3 4 Box 5 6 B...

Страница 21: ...comandato W RMS 2500 Potenza lungo termine W 1250 Potenza breve termine IEC 268 5 W 5000 Impedenza di ingresso kOhm 22 22 Impedenza nominale Ohm 4 INGRESSI USCITE Connettori di alimentazione PowerCon IN OUT PowerCon IN OUT 2 x Speakon NL4M in throu Connettori di ingresso XLR IN OUT XLR IN OUT Ingressi uscite NET NET IN NET OUT EtherCon ALIMENTAZIONE Assorbimento di rete W 650 650 Cavo di alimentaz...

Страница 22: ......

Страница 23: ...ati Italy www fbt it info fbt itwww fbt it info fbt it 23 GENERAL INFORMATIONS 23 WARNINGS 24 GENERAL FEATURES 25 Description 25 Specifications 25 DIMENSIONS 26 INPUT PANEL 27 VHA 118SND 118SN 27 VHA 118S 27 VHA 118 2SA 28 POWER SUPPLY 29 Power supply 220V 240V 29 Power supply 100 120V 29 INPUTS OUTPUTS 30 XLR Connection 30 Ethernet Connection 30 Speakon 30 NETWORKING 31 Networking of speakers 31 ...

Страница 24: ...een spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped WARNING RISK OF ELECTRIC SHOCK DO NOT OPEN TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER OR BACK NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE TH...

Страница 25: ...from all devices compatible with the DANTE standard INFINITO is a true revolution in the FBT world that enhances the user experience reaching new heights in terms of performance and simplicity It is a software platform that is fully developed in house by the FBT R D team that offers real time monitoring of the internal sensors and the status of the connected devices fast IN OUT Vu meters controls ...

Страница 26: ...CARATTERISTICHE 700mm 720mm 606mm 26 DIMENSIONS ...

Страница 27: ...D PUSH NET LINE IN IN LINK OUT VHA 118SND 1 2 3 4 5 6 VHA 118SND 118SN 1 XLR input 2 Xlr link output 3 Port compatible with EtherCON RJ45 connectors used for Ethernet network input for remote control and monitoring via INFINITO MANAGEMENT SOFTWARE 4 Port compatible with etherCON RJ45 connectors used for the daisy chain output of the INFINITO SOFTWARE MANAGEMENT remote control and monitoring Ethern...

Страница 28: ... is in operating mode YELLOW STANDBY in the absence of an input signal after 30 minutes the amplifier goes into low power consumption mode As soon as the signal exceeds the detection threshold it returns to normal mode in less than 1 second RED FAN ERROR signals an anomaly state of the fan that does not allow the amplifier to cool adequately Check if the fan is free to spin the fan may need to be ...

Страница 29: ...ND THE PLUG MUST HOLD THE UL OR CSA CERTIFICATION N max modules for connection line 3 x VHA 118SND power cord supplied 4 x VHA 118SND POWER CORD AWG12SJT W1 AC LOOP OUTPUT AC INPUT Power consumption 650 W Input Range 100 240 V 50 60 Hz 50 60 Hz 3 A 220 240 V 50 60 Hz 6 5 A 100 120 V 13 A 220 240 V 13 5 A 100 120 V M A D E I N I T A L Y CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN TO PREVENT THE RISK...

Страница 30: ...nciato femmina INPUT XLR bilanciato maschio SPEAKON Available on VHA 118S VHA 118S is a 1 way system that is it needs to be driven by an amplification channel suitably processed with DSP parameters supplied by FBT Improper use of the system with incorrect DSP settings can compromise the reliability of the transducers and exhibit suboptimal acoustic performance Internally there is no passive crosso...

Страница 31: ... cable results in the loss of control on all devices located downstream of the breakage 3 Mixed connection it is possible to use a mixed structure dividing each cluster into subgroups of devices The first device in each group is connected via NET IN to the switch then using the daisy chain structure the other elements are connected In this case an intermediate complexity network is obtained both f...

Страница 32: ...ed to control over 100 devices in the same network with automatic assignment of the IP address Features Compatible with Windows 7 8 10 Real time monitoring of sensors vu meters transducers failure etc Checking of all DSP parameters Intuitive graphical and Touch oriented interface Creation of ADVANCED and BASIC groups for extremely versatile and simple control of connected devices Instantly saving ...

Страница 33: ...SNAP 1 SNAP 2 SNAP 3 SNAP 4 EXIT Select SNAP MEM DELETE SNAP 1 SNAP 2 SNAP 3 SNAP 4 EXIT Select SNAP Push button to WINK Switch to local control Push and hold for 3 seconds Omni ANALOG Temp Protection VHA112No Omni Yes No SUB ON TYPE MANUAL SIGNAL EXT VOLUME OFF EXIT ANALOG Protection PHASE Inverted MEMORY CURRENT STATE DEFAULT LOCK SCREEN STATE OFF CONTRAST LEVEL 5 DISPLAY OFF TIME OUT 60 s ROTAT...

Страница 34: ...ONFIG PRESET SOUND PRESET PHASE DELAY IN ROUTING OUT ROUTING 1 NOISE GATE AUTO ST BY DANTE SENSORS TEST MEMORY LOCK SCREEN 2 3 VHA112 No Omni SOUND PRST SELECT Original SOUND PRST SELECT Hung DELAY VALUE 0 00 m 0 00 ms IN ROUTING SOURCE NOISE THRES LEVEL 3 dB AUTO ST BY OFF PHASE Inverted MEMORY CURRENT STATE DEFAULT SERVICE SENSORS TEST EXIT DANTE OUT ROUTING SOURCE ANALOG NOISE GATE EXIT Push bu...

Страница 35: ...ALOG Temp Protection VHA112No Omni Yes No THRES 45 dB EXIT SUB ON TYPE MANUAL SIGNAL EXT VOLUME OFF EXIT DELAY VALUE 0 00 m 0 00 ms IN ROUTING SOURCE ANALOG Protection NOISE THRES LEVEL 3 dB AUTO ST BY OFF MEMORY CURRENT DEFAULT LOCK SCREEN STATE OFF CONTRAST LEVEL 5 DISPLAY OFF TIME OUT 60 s DANTE OUT ROUTING SOURCE ANALOG DANTE RATE 48 kHz LATENCY 1 ms PCM 24 bit STATUS NO AUDIO SENSORS AMP T 26...

Страница 36: ...Y T STATE ULT EEN CONTRAST LEVEL 5 DISPLAY OFF TIME OUT 60 s ROTATION ANGLE 90 SERVICE SENSORS TEST EXIT DANTE RATE 48 kHz LATENCY 1 ms PCM 24 bit STATUS NO AUDIO S 26 C 36 C 0 RST n to INFO VHA 118SND FW 1 0 0000 TEST Ú SERVICE Ú MEMORY Y O MEM RECALL INFINITO DEFAULT SNAP 1 SNAP 2 SNAP 3 SNAP 4 EXIT MEM SAVE SNAP 1 SNAP 2 SNAP 3 SNAP 4 EXIT Select SNAP MEM DELETE SNAP 1 SNAP 2 SNAP 3 SNAP 4 EXIT...

Страница 37: ... 544 x 400 x 112 5mm Steel max 6 modules 544 x 400 x 112 5mm Steel max 3 modules VHA T 118 VHA RC 118 VHA C 118S VHA CH 118S MS F 210 VHA B 406 VHA B 406 FIXING SUPPORT MS F 210 A ground stack configuration is possible using FBT MUSE 210LND 210LN modules 37 ACCESSORIES MS J 210 FIXING SUB Steel KBW 10045 WHEELS WITH BRACKET ...

Страница 38: ...tem on a flat and non slippery surface in the case of a support surface that has a slight inclination it is necessary to adequately secure the installation with suitable mechanical means or straps Arranged for accessory mounting MS F 210 models MUSE 210LND LN on the sub Arranged for 4 mounting optional wheels Arranged for accessory mounting VHA B 406 models HORIZON VHA 406ND N e VHA 112SND SN on t...

Страница 39: ...hen the energy of the low frequencies has to be attenuated for example on the stage or in areas where it should be avoived due to noise pollution For this purpose a rea sub shall be employed every two front subs The majority of the energy generated by the rear sub is used to cancel the energy of the other two subs in the front area is equal to 1dB approximately compared to a non cardioid configura...

Страница 40: ...rformance in the 75Hz 105Hz range due to the limitation of the VHA 406ND The PUNCH pre set offers a fast and high impact bass on 60 90Hz particularly suitable in live mode CONFIG PRST SELECT 2 Way CONFIG PRST SELECT 3 Way PRESET SELECT 2 Way PRESET SELECT 3 Way HPF STATE ON SOUND PRST SELECT Low Extension ON CONFIG PRST SELECT VHA 112 Yes CONFIG PRST SELECT VHA 112 No 1Sub 1 Top 1Sub 2 Top 1Sub 3 ...

Страница 41: ...plifier W RMS 2500 Long Term Power W 1250 Short Term Power IEC 268 5 W 5000 Input impedance kOhm 22 22 Nominal impedance Ohm 4 INPUTS OUTPUTS Power supply connectors PowerCon IN OUT PowerCon IN OUT 2 x Speakon NL4M in throu Input connectors XLR IN OUT XLR IN OUT Input output NET NET IN NET OUT EtherCon POWER SUPPLY SPEC AC Power requirements W 650 650 Power cord ft 16 4 16 4 MECHANICAL SPEC Materi...

Страница 42: ......

Страница 43: ......

Страница 44: ...FBT ELETTRONICA SPA Via Paolo Soprani 1 62019 RECANATI Italy Tel 071750591 Fax 071 7505920 email info fbt it www fbt it ...

Отзывы: