Manually activate “faulty” solenoid, if doesn’t properly actuate
•
Disconnect harness from solenoid and measure supply power, range
from 22VAC to 28VAC
•
0 volt indicates faulty relay board
•
22VAC to 28VAC indicates faulty solenoid
• Faulty “shorted” solenoid will lead to a burned relay board. When
required check and replace relay board.
Troubleshooting Solenoids