F-18 battery
Istruzioni per l’uso
Instructions for use
Mode d’emploi
Manual de instrucciones
Instruções de uso
F-18 battery_User Manual_Rev.00_16.10.2019 con Alimentatore.docx
16 / 30
THE MANUFACTURER, ASSEMBLER, INSTALLER OR IMPORTER ARE HELD LIABLE FOR THE SAFETY, PERFORMANCE AND RELIABILITY OF THE
APPLIANCE ONLY IF THE ELECTRIC SYSTEM TO WHICH THE APPLIANCE IS CONNECTED COMPLIES WITH L.D.46/90
ACCESSORIES INCLUDED
CODE N°
DESCRIPTION
05.0001
JAR 1000 ML
05.00075
SET OF TUBES - AUTOCLAVABLE
05.00552
SET OF TUBES - DISPOSABLE
05.0012
SUCTION PUMP PROBE CH 16 (DISPOSABLE)
05.0016
ANTIBACTERIAL/HYDROPHOBIC FILTER (DISPOSABLE)
SP.38.06
12V ADAPTOR
SHOULD ACCESSORIES BE USED OTHER THAN THOSE SUPPLIED BY FAZZINI S.R.L., YOU MUST MAKE SURE THAT THEY HAVE THE SAME
CHARACTERISTICS AS THE ORIGINAL ONES.
NOTE: THE SUPPLIED JARS ARE NOT MEANT TO BE USED AS MEASURERS, AND PROVIDE ONLY AN INDICATION OF THE CONTAINED QUANTITY.
OPERATIONAL STEPS AT THE END OF THE PROCEDURE
NOTE: ALWAYS USE INDIVIDUAL PROTECTION DEVICES (EX. LATTICE GLOVES) EVERY TIME YOU MAY GET IN CONTACT WITH POTENTIALLY
CONTAMINATED PARTS.
1.
DISCONNECT DISPOSABLE PARTS AND DISPOSE OF THEM.
2.
CHECK THE GENERAL INTEGRITY OF THE ASPIRATOR
3.
CARRY OUT THE FOLLOWING CLEANING OPERATIONS
4.
PUT THE APPLIANCE UNDER RECHARGE
TUBES AND CONNECTORS MUST BE REPLACED FOR ANY PURPOSE.
THE FILTER ON THE APPLIANCE IS DISPOSABLE; THEREFORE IT IS NECESSARY TO REPLACE IT AFTER EVERY USE. DO NOT USE THE ASPIRATOR
WITHOUT A FILTER
JAR AND TUBE CLEANING
THE FLUID COLLECTION JAR CAN BE AUTOCLAVED AT A TEMPERATURE NOT EXCEEDING 121 ºC FOR NO MORE THAN MAX 3 MINUTES 1 ATM,
STEAM OVER THE VESSEL MAY 'BE DAMAGED. IF EXCEEDED, THE JAR MAY GET DAMAGED OTHERWISE, THE JAR CAN BE DISINFECTED WITH
DENATURED ALCOHOL OR A HYPO CHLORITE BASED SOLUTION THAT CAN BE EASILY FOUND IN PHARMACIES MAXIMUM REUSE LIMIT: 30 CYCLES
OW TO CLEAN THE APPLIANCE
DISCONNECT THE APPLIANCE FROM THE ELECTRIC SUPPLY NETWORK AND THEN CLEAN IT WITH A SOFT CLOTH WETTED WITH NON
ABRASIVE DETERGENTS
PERIODIC MAINTENANCE CHECK
THE APPARATUS 'DESIGNED TO REDUCE THE MAXIMUM MAINTENANCE OPERATIONS, BUT YOU HAVE TO DO AN INSPECTION BEFORE USE.
CONTROL ALL COMPONENTS (PIPES, TANKS AND ANTIBACTERIAL FILTER) CHECK THE SEAL OF THE CIRCUIT SWITCHING THE FAN WITH FLOW
REGULATOR IN POSITION OF VACUUM MAX. IF YOU CLOSE THE TERMINAL PART ASPIRATION THE GAUGE INDICATES THE MAXIMUM DECLARED
VOID THE UNIT IS READY FOR A NEW USE
BEFORE MAKING ANY TRANSACTION VERIFICATION IN THE EVENT OF FAILURE OR MALFUNCTION, CONTACT THE TECHNICAL SERVICE SRL FAZZINI
OR QUALIFIED BY FAZZINI S.R.L. THE BATTERY MUST BE REPLACED BY QUALIFIED PERSONNEL ONLY
FAZZINI S.R.L. MAKES NO WARRANTY OF ANY KIND FOR EQUIPMENT THAT AFTER CHECKING THE TECHNICAL SERVICE BE TAMPERED.
THE OPERATOR MUST REPLACE ONLY WHEN NECESSARY ACCESSORIES SUPPLIED IN LINE WITH THE INTENSITY 'USE OF EQUIPMENT
THE USER CONTACTS THE FAZZINI S.R.L. IN CASE OF REPAIRS NEEDED.
SHIPPING COSTS MUST BE AGREED WITH THE FAZZINI SRL BEFORE SHIPMENT OF FAILURE.
IN CASE OF PENETRATION OF LIQUIDS INSIDE THE CONTACT OF A TECHNICAL SERVICE SRL FAZZINI FOR THE NEXT MAINTENANCE.
NOT INTERVENE DIRECTLY ON THE DEVICE
STORAGE
THE ASPIRATOR MUST BE STORED IN A DRY LOCATION, PROTECTED FROM ATMOSPHERIC AGENTS