8.
Insert the air filter (1) carefully into the filter housing and
fasten it with the knurled nut (2).
9.
NOTICE!
Danger of engine damage!
–
Ensure correct fit of air filter cover and
seal.
Close the cap (3).
8.9.6 Changing the oil in the exciter housing
NOTICE!
Components may get damaged!
–
Use only oil of the permitted specification
Chapter 8.4 ‘List of fuels and lubricants’
.
–
Do not use low-ash engine oils for the exciter
shaft housing.
Protective equipment:
n
Working clothes
n
Safety shoes
n
Protective gloves
1.
Park the machine on level ground.
2.
Park the machine safely
Chapter 6.4 ‘Parking the machine
in secured condition’ on page 55
3.
Clean the area around the bleeding screw (1) and filling/drain
plug (2).
4.
Tilt the machine slightly towards the oil drain side and secure
it properly.
5.
Unscrew the bleeding screw.
6.
Unscrew the filling/drain plug and collect any oil running out.
Fig. 79
OIL
2
1
B-692-0013
Fig. 80
Maintenance – Annually / every 250 operating hours
BPR 50/55 D
83
Go