7.2 Starting with jump wires
Choose this type of starting if the starter battery is
exhausted and the machine cannot be started
manually with the safety crank handle.
NOTICE!
A wrong connection will cause severe damage in
the electric system.
The auxiliary battery must have the same voltage
as the starter battery.
Loosen the hood fasteners (1) on both sides and remove the
fasteners (2) from both sides
Fold the hood back.
Remove the battery holder and take off the vibration damping
mat.
Check vibration damping mats, brackets and screw connec-
tions, replace if necessary.
Join the plus poles on external battery and starter battery
with the jump wire
Use the second jump start cable to connect the negative
poles on external battery and starter battery.
Start the engine as described in the chapter “Starting the
engine”.
When the engine is running remove the jump start cable from
the two negative poles first and from the positive poles after.
This work sequence is necessary to avoid short cir-
cuit caused by contact between positive and nega-
tive cables.
Close the hood again and ´fasten it with bolts.