14
Practical and Useful
Information
• The sediments and limescale ac-
cumulated at the below section of
the water heater will prevent direct
contact between the water and the
heating elements. Accumulation of
sediments and limescale at the bot-
tom of the water boiler should be
prevented. The water boiler should
be drained at regular intervals.
• Heat required amount of water in
your bath stove. Install the bath
stove away from the appliances such
as refrigerator and deep-freezer.
Otherwise operation frequency will
increase.
• Ensure that isolation is installed to
prevent heat loss from the boiler and
installation.
• The water heater should be located
max. 6 m away from the points of
use. Installation on a farther location
will cause a drop at the efficiency of
heat transfer. Also the water piping
should be isolated.
• When the device is not going to be
used for a prolonged time set the
thermostat to the lowest setting.
Suggestions for Operation
• Do not place items that are vulnera-
ble to water beneath the bath stove.
• Take below precautions if you will
not use the product for a prolonged
time.
- Disconnect the product from the
mains supply.
- Switch off the water valves and dis-
connect the water connection.
Cleaning and Mainte-
nance
Disconnect from the electrical mains
before handling any operation.
• Install a transparent drain hose to the
drain output of the safety valve lo-
cated at the cold water input of the
bath stove at a location away from
freezing.
• Pressure will increase with the oper-
ation of the bath stove. Dripping of
water at the safety valve is normal.
• Drain water from the boiler setting
the safety valve latch to upright po-
sition. To check the operation of the
safety valve, it is recommended to
set the latch to upright position once
a month to see if water flows out.
• If water is drained through safety
valve, do not operate until water
comes from the hot water tap.
• To get the optimum performance
from your electrical bath stove, li-
mescale that my form on the resist-
ance due to the water hardness and
the high temperatures should be re-
moved regularly by the Authorized
Service.
Recommendations on
Energy Saving
• It is recommended to operate the
product in Eco mode (55°C) to ex-
tend the life of the product and save
energy.
• To get the best possible perfor-
mance
from the product the heat-
ing element (resistance) should be
cleaned and the magnesium bar for
corrosion protection should be re-
Содержание TCA 502
Страница 1: ...Електричен бојлер Упатство за употреба TCA 502 TCA 802 ...
Страница 20: ...20 ...
Страница 21: ...21 ...
Страница 24: ...52398409 ...
Страница 25: ...NGROHJE E UJIT ELEKTRIK MANUALI I PERDORUESIT TCA 502 TCA 802 ...
Страница 41: ...17 ...
Страница 44: ...52398410 ...
Страница 45: ...električni bojler za vodu Uputstvo za upotrebu TCA 502 TCA 802 ...
Страница 67: ...23 ...
Страница 68: ...52367695 ...
Страница 69: ...WATER HEATER USER MANUAL TCA 502 TCA 802 ...
Страница 85: ...17 ...
Страница 86: ...18 ...
Страница 87: ...19 ...
Страница 88: ...52367693 ...