4th edition, 26-08-2020
7000.05058, 4th edition, 26-08-2020
7000.05058
Installation
22
4.2.2
Connecting the Motion Control System
Connections of the Motion Control System:
Discrete inputs and outputs (for instance for discrete set-point specification or for con-
nection of limit switches and reference switches)
Communication connections
Make sure that the connection cables are not longer than 3 m.
To reduce the effects on the DC power supply network, ferrite sleeves (such as WE 742 700
790) can be used on the supply cables.
Fig. 11: EMC suppressor circuit
4.2.2.1
Power supply
Connect the Motion Control System to a sufficiently dimensioned power supply unit.
During acceleration procedures, current peaks with values up to the peak current limit
setting of the motor can occur for multiples of 10 ms.
During braking procedures, energy can be regenerated and fed back into the DC power
supply network. If this energy cannot be taken up by other drives, the voltage in the DC
power supply network will rise. A limit value for the voltage that can be fed back
during regenerative braking can be set in the Motion Control System. Alternatively the
overvoltage can be dissipated by an additional external brake chopper, see the data
sheet for the brake chopper.
L1
D1
GND
Motor
Int. Supply
U
P