2nd edition, 31-03-2020
7000.05061, 2nd edition, 31-03-2020
7000.05061
Description of functions
34
5.4.4
Maximum speed
If a speed set value is specified by means of an analogue voltage or PWM signal, it is then
possible to adjust the speed value which is to be set at 10 V DC and at a duty cycle of 100%.
In this way, the maximum speed is adapted to the application.
Different resolutions of the maximum speed value and different maximum values are possi-
ble depending on the operating mode and motor type.
Tab. 16: Motor-specific values n
setMax
Parameter
Meaning
Maximum value
Unit
Maximum speed value
(n
setMax
)
Maximum speed set value with 10 V and 100 % duty
cycle at the speed set value input U
nsoll
Motor-specific
min
-1
Motor series
Sensors
Maximum speed value
(n
setMax
)
a)
a)
Delivery state. The speed range depends on the maximum motor supply voltage.
Unit
2232…BX4(S) SC
Digital Hall
Analogue Hall
20000
20000
min
-1
2250…BX4S SC
b)
b)
Option of analogue Hall sensors is not available in this version.
Digital Hall
20000
min
-1
2250…BX4 SC
Digital Hall
Analogue Hall
10000
20000
min
-1
3242…BX4 SC
Digital Hall
Analogue Hall
20000
20000
min
-1
3268…BX4 SC
Digital Hall
Analogue Hall
10000
10000
min
-1
1525…BRC
Sensorless
20000
min
-1
1935…BRC
Sensorless
20000
min
-1
3153…BRC
Sensorless
10000
min
-1
2610…B SC
Digital Hall
10000
min
-1
2622…B SC
c)
c)
Integrated gearhead; for details, see the product data sheet.
Digital Hall
10000
min
-1
2214…BXT H SC
b)
Digital Hall
10000
min
-1
3216…BXT H SC
b)
Digital Hall
10000
min
-1
4221…BXT H SC
b)
Digital Hall
10000
min
-1