2nd edition, 31-03-2020
7000.05061, 2nd edition, 31-03-2020
7000.05061
Description of functions
26
In this configuration, the commutation signal is determined via the analogue Hall sensors.
The position information from the analogue Hall sensors is used for commutation of the
motor and for speed determination. 4-quadrant operation is possible in this configuration.
The following basic parameters are preset in this configuration:
The following settings can be made by the user:
The resolution of the analogue Hall sensors means that stable speed control is possible
from approx. 50 min
-1
.
Designation
Explanation
Set value specification
Analogue
Digital output
Frequency output
Operating mode
Speed-controlled
Speed filter
Active
Designation
Explanation
Set value specification
The following set value specifications can be set (see chap. 5.2, p. 28):
Fixed speed mode
Speed set value specification via analogue signal
Speed set value specification via PWM signal at speed set value input
Digital output
Frequency output:
The number of lines per revolution which is output at the frequency
output can be set. Possible values are 2 and 6 lines per revolution.
Fault output (see chap. 5.3, p. 31).
Operating mode
Speed-controlled
Voltage controller
2-quadrant operation with brake func-
tion
The speed is reduced by short-circuiting the motor.
Brake function can be activated/deactivated.
Speed filter
Can be activated/deactivated