Step 7.  Plug the pump in

:   

 

 
Set pump toggle switch to the 

3

 setting for the highest speed. 

 

Step 8.  Plug the pump in

:   

 
Plug the pump into a properly grounded 110 vAC outlet.   

 
Step 9.  Test pump operation

:   

 
Turn on any hot water faucet in the house to start the pump.  Turn off the faucet to stop the pump 
(assuming that the 

Bridge Valve

 has not been installed yet). 

 

Note

:  If the 

Bridge Valve

 has been installed the pump will continue to run until 95°F water 

reaches the sink where the 

Bridge Valve

 is installed.  The temperature sensor in the 

Bridge 

Valve

 will shut off and the water will stop flowing (unless a hot water faucet is open). 

 

Bridge Valve Installation

 

 

Location

The 

Advanced Bridge Valve

 should be installed under the kitchen or bathroom sink that is the 

farthest fixture from the water heater. Branched plumbing systems will need an 

Advanced 

Bridge Valve

 at the end of each line. Additional 

Advanced Bridge Valves

 are available a

www.FasterHotWater.com

  

Installation: 

1.

 

Turn off water to the house and drain the water from the pipes.  

 

2.

 

Turn off both the hot and cold angle stops (valves) below the sink.  

3.

 

Disconnect existing hot and cold water supply lines from the angle stops and replace 
angle stops with custom angle stops (see below).  

4.

 

Attach new stainless steel advanced 1/2" x 1/2" supply lines to angle stops.  

Note

: Do not use Teflon tape or pipe dope on 

Advanced Bridge Valve

 connections.  

5.

 

Attach other end of advanced supply lines to the appropriate "Cold Water In" and "Hot 
Water In" ports of the 

Advanced Bridge Valve

. Tighten finger tight plus a quarter turn 

with a wrench.   

Содержание WaterQuick Tankless

Страница 1: ...ideration how the pump will be supported and where there is access to an electrical outlet Cold Water Line If you install the circulation pump and Flow Monitor in the cold water line it must be locate...

Страница 2: ...water supply line to the water heater Step 4 Drain the hot water lines Remove the caps on the water drain valves and turn the valves to allow water to drain from the water heater Note If water continu...

Страница 3: ...pump power cord and contains the connection box that the Flow Monitor wire connects into There are 2 different styles as shown below Move Off and Auto Auto is the correct position or I Bar O and II ba...

Страница 4: ...lve should be installed under the kitchen or bathroom sink that is the farthest fixture from the water heater Branched plumbing systems will need an Advanced Bridge Valve at the end of each line Addit...

Страница 5: ...ines to the faucet Tighten finger tight plus a quarter turn with a wrench Do not over tighten 8 Leave angle stops in the off position and turn the house water back on and check for leaks 9 Open both t...

Страница 6: ...ding conductor To reduce the risk of electrical shock be certain that it is connected only to a properly grounded grounding type receptacle The safe operation of this pump requires that I be grounded...

Страница 7: ...r Hot Water s printed instructions abuse misuse misapplication improper maintenance neglect alteration accidents casualties fire flood freezing environmental factors water pressure spikes or acts of G...

Страница 8: ...imitation of incidental or consequential damages so the above limitations or exclusions may not apply This warranty gives you specific legal rights and you may have other legal rights which vary from...

Отзывы: