Air cooled water chillers and heat pumps 

with radial fans

IDRA  - RSC Series

Use, installation and maintenance manual

18

GB

SAFETY

The FAST chiller IDRA-RSC series have been designed in order to minimize all the possible risks for the operators safety. 
Please, read carefully the following instruction in order to be aware of the possible dangerous situations while operating 
with the unit.

ACCESS TO THE UNIT

Only authorized personnel are entitled to access to unit. The operators must operate with the unit using adequate safety 
devices and gear.

RESIDUAL RISKS 

The unit installation, start-up, switch-off, maintenance must respect the indications given in the product technical docu-
mentation and, in any case, preventing any possible dangerous situation. Please, consider the following possibly hazar-
dous situations.

Component

Residual risk

possible cause

precautions

heat exchange coil

small cuts

touch

avoid touch, use

protective gloves

fan grille and fan

injuries

insertion of objects 

through the grille while the 

fan is operating

do not insert any object 

through the fan grille or lay 

anything upon  it

inside the unit: compressor 

and supply pipe

burns

touch

avoid touch, use

protective gloves

inside the unit: metal 

components and electrical 

cables

intoxications, electrocu-

tions, serious burns

defect of insulation of 

supply cables upstream the 

electrical panel; metal com-

ponents under tension

adequate insulation for the 

for the supply cables; pay 

extreme attention when 

putting all the metal com-

ponents to earth

around the unit

intoxications, serious burns

fi re caused by short circuit 

or overheating of the 

supply cables upstream the 

electrical panel

cables section and protec-

tion devices of the supply 

cables as per law in force

 

 

Содержание IDRA-RSC Series

Страница 1: ...IDRA RSC Air cooled water chillers and heat pumps with radial fans Capacities from 5 kW to 17 kW USE INSTALLATION AND MAINTENANCE MANUAL GB 0509 6180588 rev 0...

Страница 2: ......

Страница 3: ...1 APPLICATION LIMITS F pg 11 SOUND PRESSURE LEVELS F pg 11 HYDRAULIC KIT pg 12 PERFORMANCE TABLES H pg 13 APPLICATION LIMITS H pg 13 SOUND PRESSURE LEVELS H pg 14 HYDRAULIC KIT pg 15 DIMENSIONS pg 16...

Страница 4: ...R407C refrigerant The high reliability of the components employed as well as the strict tests which all units must undergo grant a very high quality standard AVAILABLE VERSIONS F air cooled water chil...

Страница 5: ...luminium ns CONTROLAND SAFETY DEVICES Microprocessor with the following main functions cooling capacity control based on the inlet water temperature setting of all the operating parame ters display of...

Страница 6: ...FETY DEVICES Microprocessor with the following main functions cooling capacity control based on the inlet water temperature setting of all the operating parame ters display of chilled water inlet and...

Страница 7: ...c pressure kPa 47 0 47 0 43 0 Storage tank volume l 40 40 40 Fans Radial Number 1 1 1 Air ow m3 h 3500 3500 3500 Available static pressure Pa 115 115 109 Max input power each kW 0 52 0 52 0 52 Max inp...

Страница 8: ...ssure kPa 43 0 60 0 47 0 Storage tank volume l 40 48 48 Fans Radial Number 1 2 2 Air ow m3 h 2500 6000 6000 Available static pressure Pa 109 140 140 Max input power each kW 0 52 0 74 0 74 Max input cu...

Страница 9: ...4 Available static pressure kPa 47 0 47 0 43 0 Storage tank volume l 40 40 40 Fans Radial Number 1 1 1 Air ow m3 h 3500 3500 3500 Available static pressure Pa 115 115 109 Max input power each kW 0 52...

Страница 10: ...ailable static pressure kPa 43 0 60 0 47 0 Storage tank volume l 40 48 48 Fans Radial Number 1 2 2 Air ow m3 h 2500 6000 6000 Available static pressure Pa 109 140 140 Max input power each kW 0 52 0 74...

Страница 11: ...8 8 5 3 2 8 2 3 4 7 9 3 6 10 9 8 2 5 9 6 2 6 9 5 2 7 9 2 2 9 8 7 3 2 8 4 3 4 8 1 3 6 14 5 12 8 3 5 12 6 3 6 12 4 3 8 12 0 4 0 11 4 4 4 11 0 4 7 10 6 4 9 6 13 2 3 5 13 0 3 7 12 7 3 8 12 4 4 0 11 7 4 4...

Страница 12: ...5 26 3 440 26 HYDRAULIC KIT KEY FA water lter VS air relief valve RS discharge shut off valve SE expansion vessel SB storage tank P pump PD ow switch EV evaporator HYDRAULIC KIT Available static press...

Страница 13: ...4 9 4 2 6 9 2 2 7 8 9 2 8 8 5 3 2 8 2 3 4 7 9 3 6 10 9 8 2 5 9 6 2 6 9 5 2 7 9 2 2 9 8 7 3 2 8 4 3 4 8 1 3 6 14 5 12 8 3 5 12 6 3 6 12 4 3 8 12 0 4 0 11 4 4 4 11 0 4 7 10 6 4 9 6 13 2 3 5 13 0 3 7 12...

Страница 14: ...2 4 9 0 2 4 9 3 2 4 9 9 2 5 10 9 2 5 45 7 3 2 6 8 1 2 6 8 6 2 7 9 0 2 7 9 3 2 7 9 9 2 7 10 8 2 8 50 7 3 2 9 8 1 2 9 8 6 3 0 8 9 3 0 9 3 3 0 9 8 3 0 10 8 3 1 14 35 11 2 3 2 12 3 3 2 13 0 3 2 13 5 3 2...

Страница 15: ...static pressure kPa Flow m3 h 0 6 0 9 1 2 1 5 1 8 2 1 2 3 2 8 3 Size 5 51 47 43 7 49 45 41 9m 9 47 43 39 14 64 60 57 17 52 47 44 4 7 74 34 4 1 74 1 64 5 26 3 440 26 HYDRAULIC KIT KEY FA Water lter VS...

Страница 16: ...100 834 156 156 414 P1 P3 P1 P2 P3 P4 P1 800 500 500 400 L B 577 494 A 30 40 P2 A water inlet 1 B water outlet 1 C water line charge and discharge 1 2 E electrical cables inlet Size 5 7 9 14 17 P1 P2...

Страница 17: ...14 P1 P3 P1 P2 P3 P4 P1 800 500 500 400 L B 577 494 A 30 40 P2 Clearance A water inlet 1 B water outlet 1 C water inlet with hydraulic kit 1 D water line charge and discharge 1 2 E electrical cables i...

Страница 18: ...the following possibly hazar dous situations Component Residual risk possible cause precautions heat exchange coil small cuts touch avoid touch use protective gloves fan grille and fan injuries inser...

Страница 19: ...ork lifters or cranes When handling the unit pay special attention not to damage the condensing coil Before moving the units check their dimensions reported in the present manual It is recommended to...

Страница 20: ...hydraulic connection of the unit as shown in the gure below A water lter to be installed on the inlet pipe is to be considered as mandatory The warranty will no longer be valid if no lter is installe...

Страница 21: ...ttention to the electrical wirings drawings supplied with the units when connecting a condensing unit to the internal unit and to the room thermostat START UP Before starting the unit check the electr...

Страница 22: ...the keyboard verify the remote on off contacts are bridged and there are no alarms on the display The F H units start to operate 3 minutes after the signal given on the inlet water temperature WARNIN...

Страница 23: ...t of air perpendicularly to the coils surface to prevent damages to them and in any case pay particular attention to all the cleaning procedure If the ns are damaged line them up with a suitable tool...

Страница 24: ...1 1 7 7 7 7 7 7 72 3 3 3 1 _ 3 6 50 3 03 30 KEY C compressor F drier lter RL liquid shut off valve PA high pressure switch IL sight glass LR liquid receiver PB high pressure switch VL fans NR non ret...

Страница 25: ...below Model Max input power Power compressor pump fan total RSC F H 5 IMAX A 22 0 9 3 8 26 7 Power kW 4 2 0 08 0 52 4 8 RSC F H 7 IMAX A 17 8 0 9 3 8 22 5 Power kW 3 4 0 08 0 52 4 RSC F H 9m IMAX A 2...

Страница 26: ...r cooled water chillers and heat pumps with radial fans IDRA RSC Series Use installation and maintenance manual 26 GB SOLO SU IDRA H SOLO SU IDRA H ELECTRICAL WIRINGS IDRA RSC F H 5 7 9m TERMINAL PLAT...

Страница 27: ...r cooled water chillers and heat pumps with radial fans IDRA RSC Series Use installation and maintenance manual 27 GB SOLO SU IDRA H SOLO SU IDRA H ELECTRICAL WIRINGS IDRA RSC F H 9 14 17 TERMINAL PLA...

Страница 28: ...NKCASE HEATER HP2 2 HIGH PRESSURE SWITCH RGF1 SPEED CONTROL KAC2 RELAY RTC1 COMPRESSOR THERMAL PROTECTION KHP1 RELAY CONTACTOR RTC2 COMPRESSOR THERMAL PROTECTION KHP2 CONTACTOR RTC3 COMPRESSOR THERMAL...

Страница 29: ......

Страница 30: ......

Страница 31: ......

Страница 32: ...shown in this booklet are not binding FAST S p A shall have the right to introduce at any time whatever modi fications deemed necessary to the improvement of the product Manuale stampato su carta ric...