FV3000
3.4 Power Supply Wiring
Warning
Power Source
Make sure that the source voltage matches the power supply voltage of the FV3000 before turning on power.
Power Cable and Plug
Up to the input voltage of 125V, use the power cable and a 3P-2P conversion adapter (when being used in Japan)
supplied by FAST, to prevent electrical shock and fire. Connect the main plug to the AC outlet with a protective
ground terminal. Do not use a cable extension without the protective ground cables. If such a cable extension
is used, the protective operation will be disabled.
Protective Grounding
Be sure to ground the protective ground terminal before turning on power to the FV3000 to prevent electrical
shock. The supplied power cable for the FV3000 is a 3P power cable with a grounding conductor. Connect it to
a 3P outlet with a protective ground terminal. When the 3P-2P conversion adapter (when being used in Japan)
is used, closely connect the grounding conductor of the conversion adapter to the protective ground terminal.
Necessity of Protective Grounding
Do not cut-off the protective ground conductor inside or outside the FV3000, or disconnect the protective ground
wiring, to avoid hazards.
Warning
Be sure to observe the following to prevent damage to the machine, electrical shock or fire.
Be sure to disconnect the power cable and connection cables before connecting or disconnecting the ground
conductor.
Observe the following when handling the power cable.
(1) Do not use a damaged power cable.
(2) Do not modify the power cable or the plug.
(3) Do not place a heavy object on the power cable.
(4) Do not bend, twist or pull the cable by force.
(5) Do not place the cable near a heating apparatus.
(6) Do not connect many cables on one electrical outlet.
When the camera connected to the FV3000 is to be mounted on a robot arm, be careful with the ground connection,
so that there is no potential difference of the GND level.
When the coaxial cable used for video transmission is to be relayed using a relay connector, the GND side will
be exposed at the relay. This GND side has the same potential as that of the SG of the machine. Be careful not
to let it touch a high voltage source.
- -
19
Содержание FV3000-DOS
Страница 8: ......
Страница 13: ...FV3000 3 Mounting Fittings 2 plates with six 3 mm screws...
Страница 18: ...FV3000 8...
Страница 24: ...FV3000 14...
Страница 32: ...FV3000 22...
Страница 46: ...FV3000 36...
Страница 54: ...FV3000 44...
Страница 58: ...Ellipse hole 4 5x10 22 5 380 450 47 5 173 434 380 6 208 193 Appearance Diagram Vertically Setting...
Страница 59: ...Appearance Diagram Horizontally Setting Ellipse hole 4 5x10 22 5 450 380 173 179 6 428 453 468...
Страница 64: ......
Страница 66: ...B 001680 1437...