background image

Manual Aqua M300D 

page 27

 

 

 

 
Please ensure that your PC is connected to the Aqua M300 with the PC connecting cable, then navigate to the 

Data Transfer

 display symbol (1), confirm your selection, and follow the instructions as shown on your PC.  

 

 

 
 
 
 
 
 
 
 
 
 
 

 
 
 
 

 

 

Содержание Aqua M300 D

Страница 1: ...Manual Aqua M300D page 1 Aqua M300 D Operating Instructions...

Страница 2: ...Long Term Measuring 18 8 1 Parameter Settings for Acoustic 18 Long term Measuring 8 2 Measuring Procedure 19 9 Trace Gas Detection 19 9 1 Putting the Device into Operation 20 9 2 Display 20 9 3 Norma...

Страница 3: ...or and sludge like substance DO NOT bring the sensor head of the hydrogen sensor into contact with fine powder or powdery substances The user is solely responsible for determining whether he or she co...

Страница 4: ...nes 4 5 3 wind protected ground microphone 15 extensions with tip M10 4 universal microphone 16 adapter M6 M10 5 universal microphone with switch 17 components for hydrogen ground sensor 6 testrod 18...

Страница 5: ...This dial has two functions you can either press 3 A or turn 3 B the dual function dial Turn the dial to access menu and setting functions and to specify already selected settings Press the dial to c...

Страница 6: ...0 can be used as a ground microphone to pinpoint leaks Ground Microphone see chapter 3 legend item 3 The ground microphone 3 is a wind protected ground microphone which can be used when carrying out l...

Страница 7: ...enu and selection boxes which you can select by either using the touch screen or the navigation dial on the right When using the touch screen simply briefly place your finger on the menu or selection...

Страница 8: ...the help text you require Press the door symbol to navigate back out of the help sector If you want to leave the help sector immediately press the Cancel key You will then return to the main menu Conf...

Страница 9: ...ntered is correct and press DEL to clear the value Press the Cancel key or the door symbol on the screen to leave the setting menu 6 4 2 Languages You can select from a number of languages for the dis...

Страница 10: ...rocedure for setting the time and date as described in chapter 6 4 1 6 4 7 Touch Screen You can use this setting window to deactivate the touch screen or to carry out a calibration or performance chec...

Страница 11: ...djusting the Sensor Sensitivity To set the sensitivity of the microphone connected to your leak detection device navigate in the display window to the symbol for the sensor sensitivity setting 1 activ...

Страница 12: ...n the device is put into operation for the first time User 4 This presetting uses the filter range defined by you as the user in the frequency range settings menu see chapter 6 4 5 according to your o...

Страница 13: ...Cancel key You can also confirm the setting change by pressing the symbol for the headphone volume 1 on the touch screen A change in volume has no effect on the measuring curve and the current measur...

Страница 14: ...ent series which is made up of the last six individual measurements as well as the current measurement The first measurement saved is displayed on position 1 Each further measurement shifts the previo...

Страница 15: ...lume Mode Only the noise amplitude of the minimum value measured is displayed as a single bar in the volume mode Press the record button or the press button on the handle at the universal microphone 5...

Страница 16: ...filter frequencies at any time between individual measurements in each of the three acoustic leak detection measuring modes Navigate to the frequency range display 1 activate the display and confirm...

Страница 17: ...ones during Filter Adaptation The Aqua M300 features a function for the activation of the headphones while the filters are being set This function can be switched on or off by pressing the key on the...

Страница 18: ...owing actions on the display Set the sensor sensitivity 1 Select the filter presetting 2 Adapt the filter and activate the acoustics manually 3 Set the volume 4 Set time intervals for long term measur...

Страница 19: ...the dial on the right or by touching the touch screen with your finger and confirm your selection by pressing the dial on the right or press the Cancel key The time scale 6 on the display will now di...

Страница 20: ...ow that the hydrogen concentration is low 1 ppm H2 As soon as the sensor has reached its operating temperature the warm up bar disappears and the Aqua M300 is ready to use 9 2 Display You can read and...

Страница 21: ...er to an area with a higher hydrogen concentration The value decreases again when you move away from this area or enter adjoining areas with lower hydrogen concentrations There is a hydrogen concentra...

Страница 22: ...nger on the touch screen and pulling it to the value you wish to select Press the Cancel key to leave the window without changing the alarm threshold value Press either the dial on the right or the Ca...

Страница 23: ...1 is 250 digits the concentration in Zone 2 is 300 digits and the concentration in Zone 3 is 100 digits 1 2 3 4 1 First measuring is carried out in Zone 1 the measured value on the display is 200 dig...

Страница 24: ...most Displaying the maximum level of the current measurement numerical 1 Displaying the maximum level of the current measurement bar display 2 Time axis with displaying the PWG impulse 3 Saved measure...

Страница 25: ...p it pressed for 3 seconds All 7 positions in the display have now been cleared and are empty 11 Saving and Loading Measurement Data All measurement reading and any measurement series can be saved to...

Страница 26: ...The measuring data you have selected is now displayed 12 Transferring Measurement Data to a PC The measuring values you have saved to your internal memory can be transferred to your PC for further as...

Страница 27: ...page 27 Please ensure that your PC is connected to the Aqua M300 with the PC connecting cable then navigate to the Data Transfer display symbol 1 confirm your selection and follow the instructions as...

Страница 28: ...he batteries inside your unit with new ones of the same high quality and type 2 The central unit is defective Please contact our Customer Support Centre Display brightness too dim 1 The brightness set...

Страница 29: ...eries please make sure that you only use NIMH rechargeable batteries type HR 14 1 2 V Do not dispose of batteries in household waste Do not throw into water or fire Please make sure that you dispose o...

Страница 30: ...up to 14 hrs In non stop operation up to 40 hrs in normal operation Connections Bayonet microphone sensor 6 3mm phone jack headphones Protection class IP 54 Housing Aluminium powder coated Temperatur...

Страница 31: ...d travels is concerned As is the case with ground borne sound low frequency sounds travel further distances and softer materials like PVC or PE pipes absorb the energy caused by the leak more strongly...

Страница 32: ...n hours for the gas to reach the surface This depends on the leak and on the type of ground and surface It takes approximately 60 minutes for the gas to reach the surface when ground in green areas fo...

Отзывы: