Fast & Fluid Management B.V. – SK450 / SK550
V.
04
‐
2013
P16
Error codes
Error Cause
Action
E01
Clamping motor power too low or bad
electric wiring
Call service
E02
Preset minimal clamping pressure not
reached
Call service
E03
Door opened during mixing or door
switch defective
Keep door closed during mixing. If
persistent, call service
E04 -
E06
SK550 Mainboard 5V or 12V circuitry
overload
Call service
E07
Clamping plate reached minimal position Place (taller) can
E08
Can shrunk during mixing
Use less fragile can
E09
Component overload
Call service
E10
No pulses received from encoder
Call service
E12
T5 (turbo FET) of 100V power supply
defective
Call service
E18
Clamping plate risen or loosened during
mixing
Check can position
E20 -
E33
SK550 Mainboard component overheat
(> 90° Celsius)
Pause for cooling, check machine
ventilation. If persistent, call service
E41
EEPROM read error
Allow reset to default settings. If
persistent, call service
E71
SK550 Mainboard defective (T7 of T10)
Call service
E89
SK550 Mainboard defective (T8 of T9)
Call service
E99
Shake motor or wiring short circuit
Call service
E100
SK550 Mainboard defective (main motor
power feed)
Call service
E101
Power supply from wall socket too high
Check mains. If persistent, call service
E102
Power supply from wall socket too low
Check mains. If persistent, call service
Service and Support
If necessary, you can get in touch with your supplier or the local service department, or
contact the manufacturer directly. If you contact the manufacturer, make sure that you have
the model number and serial number to hand. They can be found on the nameplate on the
machine.
For more information please visit our website www.fast-fluid.com
Содержание SK450
Страница 1: ...Fast Fluid Management B V SK450 SK550 V 04 2013 P1 FAST FLUID MANAGEMENT SK450 SK550 ENGLISH...
Страница 19: ...Fast Fluid Management B V SK450 SK550 V 04 2013 P19 Electrical wiring diagram...
Страница 21: ...Fast Fluid Management B V SK450 SK550 V 04 2013 P21 Fast Fluid 2013 www Fast Fluid com...