9
Step 1:
Install Electrical Harness
c. Using the fuse tap & flag terminal, connect the red lead to a terminal on the
circuit board that is “hot” when the key is on.
a. The red wire of the WH-1001 wire harness will travel thru the rubber
grommet in the firewall or into the fuse panel in the engine compartment.
Note: Completion of this step will be addressed in the Mounting Step 3.
Note: Connect the fuse tap to the hot side of the fuse
b. Use a test probe to locate the “hot side” of the circuit in the fuse block.
d. Green wire must be connected to a clean ground without being exposed to
any corrosion, preferably the negative battery terminal. Secure fuse block in
a location protected from outside elements.
e. Route wire harness along frame rail to mounting location of pump.
Note: The use of a corrosion preventative on electrical connections is rec-
ommended.
Note: The installation of the electrical harness is done first, allowing power to be applied to the pump
for lubrication purposes later in the installation.