MAINTENANCE
CAUTION :
The “spare parts” handbook does not authorize users to carry out work on the
machine with the exception of those expressly described in the user manual. It
only enables users to provide the technical assistance service with precise in-
formation in order to minimize delays.
WARNING :
FAS
EP
declines all liability for claims deriving from the use of non-original
spare parts or accessories.
CAUTION :
Any operation intended to modify the setting value of the relief valves or pres-
sure limiter is forbidden .
F
A
S
EP
srl declines all liability for damage resulting from tampering with the-
se valves.
CAUTION:
In case of replacement of the power supply cable, follow the indications listed
in the table below for the most appropriate cable choice:
SUPPLY
CABLE TYPE
N° OF WIRES
WIRE SECTION
400/3/50
400/3/60
230/3/50
230/3/60
200/3/50
200/3/60
FROR 450-750 V
UNEL 35011
H07RN-F
CEI 20-27
3 - phase
1 - gounding
1 mm²
240/1/50
230/1/50
220/1/60
FROR 450-750 V
UNEL 35011
H07RN-F
CEI 20-27
1 - phase
1 - neutral
1 - grounding
1,5 mm²
115/1/60
UL 1569 300V
105°C
1 - phase
1 - neutral
1 - grounding
AWG 14
CAUTION :
Do not remove or modify any parts of this equipment except in the case of ser-
vice operations.
21
Содержание RASE.TOP.2248
Страница 13: ...DECALCOMANIE 13 9 10 1 2 3 4 9 23 8 5 6 10 11 12 13 18 14 15 16 17 17 19 20 21 22 7...
Страница 38: ...LABELS 13 9 10 1 2 3 4 9 23 8 5 6 10 11 12 13 18 14 15 16 17 17 19 20 21 22 7...
Страница 52: ...SCHEMA ELETTRICO ELECTRIC SCHEME 27 S 40 2 P...
Страница 53: ...28 SCHEMA ELETTRICO ELECTRIC SCHEME S 40 2 P...
Страница 54: ...SCHEMA ELETTRICO ELECTRIC SCHEME S 40 2 E 29...
Страница 55: ...SCHEMA ELETTRICO ELECTRIC SCHEME S 40 2 E 30...