TROUBLE SHOOTING
CAUTION :
In case of unexpected failure, electrically insulate the machine by means of an
omni polar disconnection device.
TURNTABLE NOT TURNING :
.
Feeding plug not connected or defective:
- check the plug
Machine not powered:
- Restore the electric connections.
Defective inverter :
- replace the inverter, (skilled staff needed in this case)
Motor shorted:
- replace the motor, (skilled staff needed in this case)
Belt broken:
- Replace the belt
ROTATION CONTROL PEDAL FAILS TO RETURN TO CENTRAL POSITION:
.
Control spring broken:
- Replace the control spring.
BEAD BREAKER PEDAL AND TABLE TOP PEDAL DO NOT RETURN TO HOME POSITION :
.
Control spring broken:
- Renew the spring.
No oil in lubricator:
- Top up lubricator with SAE20 non-detergent oil .
AIR LEACK INSIDE THE MACHINE :
.
Air leak from bead breaker cock:
- Renew the cock.
- Renew bead breaker cylinder.
Air leak from the table top cock:
- Renew table cock unions.
- Replace the cock.
23
COLUMN TILTS VIOLENTLY OR TOO SLOWLY :
.
Incorrect release valve setting:
- Adjust air delivery regulators on control valve.
ELECTICAL BEAD BREAKER MOTOR NOT OPERATE :
.
Blown fuses:
- Replace the fuses type 10,3x38 16 A.
Defective inverter :
- Replace the inverter, (skilled staff needed in this case)
Motor shorted:
- Replace the motor, (skilled staff needed in this case)
Limit microswitch defective:
- Replace the limit microswitch , (skilled staff needed in this case)
Содержание RASE.2247
Страница 13: ...DECALCOMANIE 9 10 13 1 2 3 4 13 18 14 15 9 19 8 5 6 10 11 12 16 17 7...
Страница 36: ...LABELS 13 9 10 1 2 3 4 13 18 14 15 9 19 8 5 6 10 11 12 16 17 7...
Страница 48: ...SCHEMA ELETTRICO ELECTRIC SCHEME 25 S 40 1 P...
Страница 49: ...26 SCHEMA ELETTRICO ELECTRIC SCHEME S 40 1 P...
Страница 50: ...SCHEMA ELETTRICO ELECTRIC SCHEME S 40 1 E 27...
Страница 51: ...SCHEMA ELETTRICO ELECTRIC SCHEME S 40 1 E 28...