General Safety Requirement
[
before using/servicing this unit
]
1.
Read this instruction manual before operating or servicing the wheel balancer.
2.
Make sure electrical power source conforms to requirements shown on nameplate (see also model identification chart for
reference).
3.
Make sure the unit has a stable position and it
’s bolted to the ground.
[when using the unit]
4.
Protect power leading to the unit from damage.
5.
When work area is being washed, make sure unit is adequately protected.
6.
Remove all stones and mud lodged in tire treads before balancing the wheel.
7.
Do not touch spinning wheel.
8.
Make sure counterweights are securely attached before checking residual unbalance.
[when servicing the unit]
9.
Make sure power sources are disconnected before service on the unit is performed.
10.
Service to PCB, electrical and mechanical parts should be done only by an Authorized FASEP 2000 Service Center.
C:
Errors and Malfunctions recognized by the Computer
Errors may apply to some model only.
ERR 1
Shaft does not rotate
ERR 16
Calibration memory error
ERR 2
Rotation Direction is wrong
ERR 17
Rod in uncorrected position
ERR 3
Rotation speed is not ready
ERR 18
Excessive weight detected
ERR 4
Rotation speed is wrong (too low or too high)
ERR 19
Reserved
ERR 5
Position Sensor or Position Disk failure
ERR 20
Excessive Deceleration
ERR 6
Safety Safety cover is open
ERR 21
Error in inputting data
ERR 7
Measuring cycle was interrupted
ERR 22
Brake error
ERR 8
Calibration weight was not inserted
ERR 23
Reserved
ERR 9
Activation code not correct
ERR 24
Insufficient air pressure (PL version)
ERR 10
Overflow in calculations
ERR 25
Reserved
ERR 11
Serial number is wrong
ERR 26
Piezo sensor error
ERR 12
Serial number not inserted
ERR 27
Wheel
is not securely tightened
on the shaft
ERR 13
Reserved
ERR 28
Laser error
ERR 14
Uncorrected password
ERR 29
Reserved
ERR 15
E²prom error
For a complete and updated list of error codes on the machine together with resolution procedure, please visit