CALIBRATION
4.1
How to calibrate the Wheel Balancer (USER)
NOTE:
the following symptoms indicate need for calibration:
a) check calibration program fails.
b) constant low or high weight readings.
c) indicated point of unbalance constantly wrong
d) more than 2 spins required to balance wheels repeatedly
Switch on the wheel balancer.
Press
<SET>
when
SOF
X.XX
(software version) is displayed.
ATTENTION
select mode
CAL USR
Spin the empty shaft (Fig. 7).
Place a wheel on the flange ( Fig. 8).
Put the calibration weight ( Fig.9 ).
End of calibration.
Press
<MODE/ESC>
to return to normal
balancing mode.
NOTE
technical calibration is only available for qualified personnel.