background image

 

 

Installation 

 

 

18 

Installation instructions Sauna control Series FCUxx00 / Version V 2.27 

 

5.6 

Assembly (

I

) / disassembly (

II

) of operating control FCUxxxx-Design 

 

Figure 4:Assembly / disassembly of operating control FCUxxxx-Design 

Содержание FCU 00 Series

Страница 1: ...e always accessible Technical changes and errors excepted illustration similar Series FCUxx00 Installation instructions Sauna control Series FCU2000 FCU2200 Series FCU3000 FCU3200 FCU3400 Series FCU40...

Страница 2: ...2 Installation instructions Sauna control Series FCUxx00 Version V 2 27 FASEL GmbH Germany...

Страница 3: ...on 15 5 1 ESD protection 15 5 2 Installation of sauna control device FCUxxxx 15 5 3 Installation of the operating control of FCUxxxx Design 15 5 4 Installation opening of operating control FCUxxxx Des...

Страница 4: ...sauna control 32 7 4 Functional test of the sauna control device and the electrical consumers 33 7 5 Functional test of the sensor 34 8 General Information 35 8 1 Liability limitation 35 8 2 Copyright...

Страница 5: ...s personal injuries and property damage DANGER indicates an imminent dangerous situation which could lead to loss of life or cause serious injuries if not avoided WARNING indicates a possible dangerou...

Страница 6: ...e thermostat must be installed in such a way that it is not affected by the incoming cool air 1 3 Intended use Depending on the version the FASEL sauna controls of the series FCU2x00 FCU3x00 and FCU4x...

Страница 7: ...oned Technical personnel Due to their technical training knowledge and experience as well as the knowledge of the relevant regulations these persons are in a position to carry out the tasks assigned t...

Страница 8: ...itch off the fuse in the distribution box and secure against restarting Check for zero potential The control device should be disconnected from the mains before opening the casing In case of damage to...

Страница 9: ...or interior display m 100 Voltage supply V AC Hz see nameplate Number of temperature sensors 1 2 IR sensor safety OFF C Sensor interruption at ca 138 C sensor short circuit at ca 25 C STB interruption...

Страница 10: ...e Cross section Number of leads H07RN FG2 5 heavy rubber hose 2 5 mm 2 Power supply cables must be polychloroprene coated and should not be lighter than heavy polychloroprene coated flexible cables 23...

Страница 11: ...t max 10A for 5ms Color light 3 OUT 13 OUT 16 C5 230 V max 120 W per relay total capacity see circuit diagram Inrush current max 150A for 20ms OUT 1 OUT 4 3 OUT 5 OUT 12 3 Potential free safety extra...

Страница 12: ...or at another location however not within the cabin If the installation is not done directly on the outer wall of the cabin then the following points should be noted Lay the signal cables separately...

Страница 13: ...ol unit on the left side Fig 2 Control unit nameplate 1 Type designation 2 Company logo 3 Article number 4 Voltage and max power 5 Device number 6 Barcode 7 article number 8 Barcode article number 9 V...

Страница 14: ...should be taken The consignment should not be accepted or accepted conditionally only Note down the scope of damage on the transport documents or on the delivery note of the transporter Initiate clai...

Страница 15: ...ow at a distance of at least 5 cm from the walls or other equipment There should be a distance of 10 cm between other electrical devices The sauna control device must be mounted on a closed surface no...

Страница 16: ...structions Sauna control Series FCUxx00 Version V 2 27 5 4 Installation opening of operating control FCUxxxx Design and FCUxxxx Design Glas Figure 3 Installation opening for operating control FCUxxxx...

Страница 17: ...Installation Installation instructions Sauna control Series FCUxx00 Version V 2 27 17 5 5 Installation opening of operating control FCU5x00 Touch...

Страница 18: ...ion 18 Installation instructions Sauna control Series FCUxx00 Version V 2 27 5 6 Assembly I disassembly II of operating control FCUxxxx Design Figure 4 Assembly disassembly of operating control FCUxxx...

Страница 19: ...Installation Installation instructions Sauna control Series FCUxx00 Version V 2 27 19 5 7 Assembly I disassembly II of operating control FCUxxxx Design Glas and Touch I II...

Страница 20: ...g air Note The temperature and humidity values displayed on additional thermometers and hygrometers in the cabin can deviate from the displayed values on the control This could be due to the following...

Страница 21: ...dditionally install one STB Safety Temperature Limiter U2 5cm below the grating of the airshaft 2 Sensor System U2 Unless a different position is specified by the oven manufacturer install it on the w...

Страница 22: ...n Figure 7 Installation location for humidity sensor combined bench sensor Humidity sensor Install the humidity sensor on the wall on the opposite side of the evaporator at approximately 1 35 1 60 m h...

Страница 23: ...marking on the back side is aligned to the top When the mounting plate is fixed wrongly pent up water can not drain 4 Depending on the sensor used connect the signal cable to the board as per the circ...

Страница 24: ...nal display directly over or next to the oven Do not install the internal display in front of the infrared heater Cabin interior display must be installed vapor tight Seal with silicone Installation I...

Страница 25: ...ocket 1 2 Drill with box drill 3 4 Saw out the left standing center bars with a jigsaw Electrical Connection Connect the RJ45 connector of the internal display with a patch cable to the control device...

Страница 26: ...against restarting Check for zero potential The control device should be disconnected from the mains before opening the casing In case of damage to the insulation switch off the power supply immediate...

Страница 27: ...igh interferences If you connect inductors like e g a magnet valve relay transformer throttle or engine the interferences of the consumers must be suppressed 6 2 Connecting the control device consumer...

Страница 28: ...igure 12 Connection of oven sensor for temperature and bench sensor for temperature Figure 13 Connection of cover guard for sauna oven detailed installation and connection Instructions refer the docum...

Страница 29: ...ersion V 2 27 29 Electrical circuit diagrams for sensor Figure 15 Connection of bench sensor for humidity Figure 16 Connection of combined bench sensor for temperature and humidity Electrical circuit...

Страница 30: ...Electrical connection 30 Installation instructions Sauna control Series FCUxx00 Version V 2 27 6 3 Electrical circuit diagram Figure 18 Electrical circuit diagram...

Страница 31: ...ith a contact opening width corresponding to the requirements of the excess voltage category III for total disconnection Disconnect the unit from the mains before carrying out any work on it switch of...

Страница 32: ...ure and humidity sensor Ensure unrestricted air circulation 7 2 Checks before the initial commissioning The following points should be checked before the initial commissioning Does the voltage supply...

Страница 33: ...tch on and switch off the electrical consumers through the corresponding operating keys on the sauna control or the operating control Check the rotating direction of the fan Check the function of the...

Страница 34: ...ignal is sounded and an error message is displayed on the display See also operating manual Series FCU2x00 FCU3x00 FCU4x00 Check the display of the temperature value therefore press and hold down the...

Страница 35: ...e delivery terms of the manufacturer and the legal regulations valid at the time of concluding the agreement are applicable Guarantee The guarantee period of the manufacturer starts from the time of d...

Страница 36: ...r Repairs of the sauna control should be carried out only by the technical experts Obtain spare parts from the installer or the dealer of the sauna unit For address see the invoice delivery note or th...

Страница 37: ...ght dimming clamp 3 enabled Light dimming disabled only ON OFF The jumpers are located only on one side of the pins as in the picture above or they are in the by pack kit of the control unit Disable u...

Страница 38: ...it diagramm 30 Electro magnetic damage 27 Explanations of symbols 5 F Functional test Consumers 33 Sauna control device 33 Sensor 34 G General Information 35 Goods receipt 14 Guarantee 35 H Humidity s...

Страница 39: ...Notes Installation instructions Sauna control Series FCUxx00 Version V 2 27 39 Notes...

Страница 40: ...Address of the contractor installer or the dealer of the sauna unit...