USE AND MAINTENANCE MANUAL - SECTION 3
STOCK PICKER ELEVAH 65-80 MOVE PICKING – Rev. 09_2019
Page 3-3
FUNCTIONAL TEST
At the end of the "DAILY INSPECTION" (section n°6), carry out a functional
test of all plants in an area free from overhead obstacles and at ground level.
ATTENTION
IF THE MACHINE DOES NOT WORK PROPERLY, SWITCH IT OFF
IMMEDIATELY. WARN MAINTENANCE PERSONNEL OF THE PROBLEM. DO
NOT USE THE MACHINE UNTIL IT IS DECLARED SAFE TO USE.
Carry out a functional test as detailed below.
1. Check the correct operation of the manual descent valve
(EMERGENCY DESCENT).
2. From the control console of the cage, carry out the detailed
operations.
a.
Ensure the control console is correctly assembled and securely
fastened;
b.
Lift and lower the cage checking lifting and lowering happen
regularly;
c.
Ensure all machine functions are disabled when activating
(pressing) the emergency stop button.
d.
Activate all functions and check the correct operation of all end run
switches, main and activation switches.
Machine brakes – Drive the machine on a slope (not exceeding
the nominal functioning capacity on a slope) and stop it to
ensure the brakes hold it;