USE AND MAINTENANCE MANUAL - SECTION 4
STOCK PICKER ELEVAH 65-80 MOVE PICKING – Rev. 09_2019
Page 4-6
General information
Before operating the machine from the cage control console, the following
conditions of the controls must be met:
The master switch must be ON.
The emergency stop switch with removable key, located on the
control station in the cage must be on RESET.
Emergency stop/switch-off button with removable key
The emergency button located inside the control console of the cage is
provided with a removable key to prevent the machine from being used by
unauthorised personnel. Press the button and remove the key to disconnect
the general power supply.
POWER SUPPLY DISCONNECTION
PUSH INWARDS to engage the emergency
stop and remove the key to prevent
unauthorised use.
POWER SUPPLY CONNECTION
Insert the key and TURN clockwise and
RELEASE to restore the emergency stop.
NOTE: in order for the machine to operate, the emergency stop button on
the cage must be on RESET.