ENGLISH
ENGLISH
GB-19
GB-18
based on the hardness of the water used. This is
intended to optimise and customise the level of
salt consumption.
Please follow the steps below for adjustment in
salt consumption.
1.
2. Press the tart/pause button for more than
5 seconds to start the water softener set
model within 60seconds after the appliance
is switched on (The Salt and Rinse aid
warninglights will be on periodically when it
get in the set model);
3. Press the Program button to select the proper
set according to your local environment, the
sets will change in the following sequence:
H ->H ->H ->H ->H ->H ;
4. Press the Power button to end the set up
model.
WATER HARDNESS
Selector Position
Salt
consumption
(gram/cycle)
°dH
°fH
°Clarke mmol/l
0~5
0~9
0~6
0~0.94 H1--Rapid indicator
lights
0
6-11
10-20 7-14
1.0-2.0 H2--90Min indicator
lights
9
12-17
21-30 15-21 2.1-3.0 H3--90Min, Rapid
indicators light
12
18-22
31-40 22-28 3.1-4.0 H4--Glass indicator
lights
20
23-34
41-60 29-42 4.1-6.0 H5--Glass Rapid
indicators light
30
35-55
61-98 43-69 6.1-9.8 H6--Glass 90M
inindicatosr light
60
Note:1
1°dH=1.25 °Clark =1.78°fH=0.178mmol/l
dH: German degree
fH : French degree
Clark: British degree
Note:2
The manufactory setting: H4 (EN 50242).
Contact your local water board for information
on the hardness of your water supply.
Close the door, Switch on the appliance;
4
5
6
1
2
3
s