10 / 52
www.fanvil.com
immediately.
Here the feature of “pressing * to send the call” could be disabled by the option “press * to send”
under EGS setting -> Features -> Basic Settings
Another 2 important options are “dial Fixed Length to Send” and “send Length”. When user is
typing in the number under dialing mode on keypad, device will check the length of number after
every new digit was typed. Once the length matches the parameter “send Length”, the number
will be called immediately. If this feature is disabled, user will need to wait “auto dial out time”
seconds before the call is sending out.
2) By pressing the DSS key, the preconfigured number will be called. The option is under
Function Key -> Function Key settings. The type is hot key, subtype is Speed dial. There are
2 numbers available here, the number 1 will be called first, if number 1 is not answered, the
call will be transferred to number2.
3. End call
The key “#” is used to end the active call. There are another 2 important features:
1) Release the processing call
2) Reject the incoming call when it’s ringing
4. Open the door operation
There are seven options to open the door:
1)In idle state, Input “local password” on the keyboard to open the door, it could be configured
under EGS Setting -> Feature -> Local Password.
2) Open with remote password. Make a call to the owner, the owner enters the remote password
to open the door. “remote password” could be configured under EGS setting -> Feature ->
Remote Password.
3) Open with Access code. The owner makes a call to the access control, the access control will
answer the call automatically. Then owner enter the “access code” on his keypad to open the door.
The owner’s number and access code are configured under EGS Access -> Access Table & Add
Access rule.
4) Swipe the RFID/IC cards to open the door. Before user can use the card, it must be added
under EGS Access -> Access Table.
5) By pressing the indoor switch to open the door. The indoor switch must be connected correctly
according to the section 1.
6) Private access code to open the door.
The private access code could be configured under EGS Access -> Access Table & Add
Access Rule. To open door with private access code, user enter “location code” + “*” +
“Access Code”. For example, the location code is 1, and Access code is 123, User enter
“1*123#” to open the door.
NOTE: ended with “#” to send the code immediately.
7) Active URL control command to open the door.
Содержание i23S
Страница 1: ...SIP Audio Door Phone i23S USER MANUAL V1 0 www fanvil com ...
Страница 2: ...Document VER Firmware VER Explanation Time V1 0 2 1 1 3445 Initial issue 20180208 ...
Страница 15: ...15 52 www fanvil com Auto Provision Field Name Explanation Common Settings ...
Страница 25: ...25 52 www fanvil com ...