2
ture (comfort) with parallel translation of the heating
curve. Potentiometer to regulate nighttime ambient
temperature (economy). Six-way selector to select
the operating program, switch to select burner ON/
OFF control or mixing valve proportional control. Po-
tentiometer to regulate the delay in circulation pump
shutdown. Pilot lamps, quick connection to the base
by means of FASTONS, casing and base in insulat-
ing material with transparent cover. Protection: IP40;
installation: wall, flush or rear panel mounting.
TECHNICAL DATA
- Control unit consumption: 5VA.
- Supply voltage: 230V ± 10% - 50Hz.
- Compliance with CEI EN 60730-1 Standards
- Daily programming through quartz clock with 100
hours charge.
- Mixing valve control by 2 relays
- Contact rating: 5A 230V~ (ohmic charge), voltage
free.
- Max ambient temperature: T50.
- Protection degree IP40.
- Pollution degree 2.
- Impulse voltage 4000V.
BASE REMOVAL
REAR PANEL MOUNTING
WALL MOUNTING
FLUSH MOUNTING
OVERALL DIMENSIONS
110
110
55 55
138
138
60
138
138
91
93
4,5
144
144
136