TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT
30
CH180RFWIFI
7.12 - EXTERNAL PROBE
The CH180RFWIFI does not have an auxiliary input but, inside a multi-one system with at least one CH120RF, it can
manage the auxiliary input of the CH120RF itself, if correctly configured (see "ANTI-CONDENSATE ADJUSTMENT" and
"EXTERNAL PROBE" in the CH120RF manual).
Note:
in a multi-zone system only CH120RF associated to zone 2 can be configured with external probe set as remote
probe for CH180RFWIFI.
■
--- = action disabled
Connecting to CH120RF you can use the following functions after connecting an EC18-EC19-EC20 temperature probe:
■
DEW = floor system condensate formation control in summer through control of the dew point (a floor probe is required).
Note:
with the control active, when a zone switches the cooling system off, the symbol flashes in the corresponding
zone.
■
LOW = minimum safety temperature exceeded alarm. This is a safety threshold, only active in the SUMMER season and
disables the system. To activate, press OK and set the desired minimum threshold using the
or keys.
■
HIGH = maximum safety temperature exceeded alarm. This is a safety threshold, only active in the WINTER season and
disables the system. To activate, press OK and set the desired minimum threshold using the
or keys.
Connecting to CH120RF a voltage-free contact allows you to use the following functions:
■
CHG O = switch-over to SUMMER mode with closed contact and WINTER mode with open contact
■
ALR O = display of alarm message in presence of open contact
■
ALR C = display of alarm message in presence of closed contact
EXT IN: ---
ESC
2s
2
1
12:01 01-01-18
23.0
1
36
DAY
[ MAN ]
MODE
DISP
PROG
ZONE
OFF
ESC
RH%
ADVAN PROGR
LIGHT ON 30S
ESC
LIGHT ON 30S
INT LIGHT 5
DAY SVNGS YES
TA = 5.0
RH = ---
RELAY: OFF
ZONE NAMES
OFFSET
DIFF: STD
CELSIUS
ENGLISH
EXT IN: ---
COOL OFF NO
AUX1: MAN
ZONE DEU
WIFI: A.P.
CH180RW V1.0
RESET NO
PRESS
x11
PRESS
ESC
---
DEW
CHG 0
ALR 0
ALR C
LOW
HIGH
3s