8
Fastening the socket
The thermostat is supplied complete with a
socket suitable for mounting both on the wall
and to rectangular or round built-in 3-seat
boxes (503).
Remove the thermostat top cover.
Separate the thermostat socket and front by
removing the screw by means of a suitable tool
and taking the front part off.
Fasten the socket to the desired surface by
means of the special fastening holes; make
sure that the socket is properly engaged, with
no deformation, and that the connecting multi-
pole connector is located in the right bottom
DRILLING CENTERS
BATTERY
COMPARTMENT
SCREWS
SOCKET
FASTENING
HOLES
MULTI-POLE
CONNECTOR
corner.
To ensure correct operation, the socket shall
be placed at a height of approximately 1.5 me-
tres from the
fl
oor, far from heat sources (direct
sunlight, etc.) and doors/windows.
Electric connections
External probe connection
Connect the two external probe wires with
screwed terminals “1” and “2”, as illustrated in
the
fi
gure. Such probe can be con
fi
gured as
external probe or minimum temperature con-
tact. See the “thermostat con
fi
guration” para-
graph, P02 parameter.