Switch (Dual) is entering into pairing mode.
3. If the In-Wall Smart Switch (Dual) has been successfully added to your Z-Wave network, its
RGB LED will be solid. If the pairing was unsuccessful, the red LED will be on for 2 seconds
and then remain a colourful gradient, repeat the instructions above from step 1.
With your In-Wall Smart Switch (Dual) now working as a part of your smart home, you’ll be able
to configure it from your home control software/phone application. Please refer to your software’s
user guide for further instructions on configuring In-Wall Smart Switch (Dual) to your needs.
Removing In-Wall Smart Switch (Dual) from a Z-Wave network.
Your In-Wall Smart Switch (Dual) can be removed from your Z-Wave network at any time. You’ll
need to use your Z-Wave network’s main controller. To set your Z-Wave controller/gateway into
removal mode, please refer to the respective section within your controller instruction manual.
1. Set your Z-Wave controller into removal mode.
2. Press the Action Button on the In-Wall Smart Switch (Dual) or toggle the external manual
switch 3 times in fast succession.
3. If the In-Wall Smart Switch (Dual) has been successfully removed from your Z-Wave network,
its RGB LED will remain colourful gradient. If the removal was unsuccessful, the RGB LED
will still be solid (following the state of the output load), repeat the instructions above from
step 1.
Advanced functions.
Changing mode on the External Switch/Button Control.
The In-Wall Smart Switch (Dual) can be controlled via 2-state (flip/flop) external/manual switch,
momentary push button or the 3-way switch. To automatically detect and set the mode to the
appropriate type of manual switch wired into In-Wall Smart Switch (Dual), toggle the button on
the manual switch once and wait 2 seconds for the In-Wall Smart Switch (Dual) to detect the type
of manual switch.
You can also set the external switch mode through Configuration Command Class.
Parameter 120 [1 byte dec] is the parameter that will set one of the 3 different modes
for external
switch S1. If you set this configuration to:
(0) Unknown mode
(1) 2-state switch mode
(2) 3-way switch mode
(3) Momentary push button mode
(4) Enter automatic identification mode. (The blue LED will fast blink)
The parameter 121 [1 byte dec] is the parameter that will set one of the 3 different modes for
external switch S2. If you set this configuration to:
(0) Unknown mode
(1) 2-state switch mode
(2) 3-way switch mode
Содержание FT132
Страница 1: ...In Wall Smart Switch Dual...