Fantech FQ110 Скачать руководство пользователя страница 1

FQ Series
Quiet Exhaust Fans  
and Fan-Lights

1.  Use this unit in the manner intended by the manufacturer. If you have 

any questions, please contact the manufacturer .

2.  Before servicing or cleaning unit, switch power off at service panel 

and lock the service disconnecting means to prevent power from 
being switched on accidentally. When the service disconnecting 
means cannot be locked, securely fasten a prominent warning 
device, such as a tag, to the service panel.

3.  Installation work and electrical wiring must be done by qualified 

person(s) in accordance with all applicable codes and standards, 
including fire-rated construction.

4.  Sufficient air is needed for proper combustion and exhausting of 

gases through the flue (chimney) of fuel burning equipment to pre-
vent back drafting. Follow the heating equipment manufacturer’s 
guideline and safety standards such as those published by the 
National Fire Protection Association (NFPA), and the American 
Society for Heating, Refrigeration and Air Conditioning Engineers 
(ASHRAE), and the local code authorities.

5.  When cutting or drilling into wall or ceiling, do not damage electrical 

wiring and other hidden utilities.

6.  Ducted fans must always be vented to the outdoors.
7.  If this unit is to be installed over a tub or shower, it must be marked 

as appropriate for the application and be connected to a GFCI 
(Ground Fault Circuit Interrupter) – protected branch circuit.

8.  NEVER place a switch where it can be reached from a tub or shower.
9.  This fan must be properly grounded.
10.  Do not use in the cooking area (Figure. 1).

Floor

Cooking 

Equipment

Cooking area

Do not install above 

or inside this area

45

45

Figure 1

11.  Do not block the air intakes or exhaust.
12.  Power supply wiring is to be No. 14 AWG wire or larger (suitable 

for at least 90°C (190°F) ).

13.  Not for use outdoors.
14.  For lighted units, use only CFL type T4, 26W lamp and a maxi-

mum 4 W night light .

15.  The fan must not be installed in a ceiling with an “R” rating 

greater than 40.

16.  The fan is type IC (Inherently Protected).
17.  To reduce the risk of injury, install the fan at least 7 feet (2.1m) 

above the floor.

18.  Acceptable for use over a shower or tub when installed in a GFCI 

protected branch circuit.

19.  The fan should not be turned on or off rapidly.
20.  Do not clean the fan with corrosive chemicals or water in excess of 

60° C (140° F).

21.  If the fan is not operating properly, shut the power off immediately, 

and have a certified installer inspect it and have it serviced as 
required.

22.  These fan must be mounted to structural members that are strong 

enough to support the fan’s weight.

23.  Do not allow foreign objects to enter the fan; this could result in 

electric shock or fan damage.

READ AND SAVE THESE INSTRUCTIONS!

Read carefully all instructions before installing or using this product 

FQ Series Fan

FQ Series Fan-Lights

Package Includes:

1  Fantech Exhaust Fan or Fan-Light
5  Mounting Brackets
8  Mounting screws
1  26W CFL Type T4 (Fan-Light models only)
1  4w night light (Fan-Light Models only)

WARNINGS:

  BEFORE INSTALLATION, TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

CAUTION

:  

1.  For general ventilating use only. Do not use to exhaust haz-

ardous or explosive materials and vapors.

2.  This product is designed for installation in flat ceilings only. 

Do not install it in a sloping ceiling or in a wall.

3.  To avoid motor bearing damage and noisy unbalanced impel-

lers keep construction material / dust from entering the fan.

4.  Please read specification label on the product for further 

information and requirements.

Содержание FQ110

Страница 1: ...ir intakes or exhaust 12 Power supply wiring is to be No 14 AWG wire or larger suitable for at least 90 C 190 F 13 Not for use outdoors 14 For lighted units use only CFL type T4 26W lamp and a maxi mum 4 W night light 15 The fan must not be installed in a ceiling with an R rating greater than 40 16 The fan is type IC Inherently Protected 17 To reduce the risk of injury install the fan at least 7 f...

Страница 2: ...f the keyhole on each bracket on the joists NOTE The bottom edge of the housing should be flush with the bottom of the joist Figure 4 4 Remove the housing and drive the screws part way into the joists at the marked locations Figure 5 e box cover Hanger bar Insert Suspension bracket Figure 3 1 Figure 3 2 Plug in Figure 5 Wire box cover Hanger bar ist Insert Suspension bracket Figure 3 1 Figure 3 2 ...

Страница 3: ...y to the housing To clean the impeller and housing remove the motor and then wash with water or a neutral detergent as required NOTE Keep all electrical components away from water Do not use corrosive chemi cals or water in excess of 60C 140 F to clean plastic parts For Fan Light Combination For Fan Only Units Fan Specifications Model Power Consumption W Airflow CFM Power Motor Light CFL Night Lig...

Страница 4: ...48 Industrial Blvd Lenexa KS 66215 Phone 800 747 1762 913 752 6000 Fax 800 487 9915 913 752 6466 www fantech net info fantech net Canada 50 Kanalflakt Way Bouctouche NB E4S 3M5 Phone 800 565 3548 506 743 9500 Fax 877 747 8116 506 743 9600 www fantech net info fantech net This warranty does not apply to any FANTECH INC product or part which has failed as a result of faulty installation or abuse inc...

Страница 5: ... moins 90 C 190 F 13 Ne doit pas être utilisé à l extérieur 14 Pour les unités à éclairage utiliser uniquement des lampes fluorocompactes de type T4 de 26 W et une veilleuse de 4 W maximum 15 Le ventilateur ne doit pas être posé dans un plafond avec classement R supérieur à 40 16 Le ventilateur est de type à protection intrinsèque IC 17 Pour réduire le risque de blessure installer le ventilateur à...

Страница 6: ...ARQUE Le bord inférieur du boîtier doit affleurer le bord inférieur de la solive Figure 4 4 Retirer le boîtier et enfoncer les vis à mi course dans les solives aux endroits marqués Figure 5 vercle du boîtier âblage Barre de suspension e Insertion de support de suspension Figure 3 1 Figure 3 2 Plug in Figure 5 Couvercle du boîtier de câblage Barre de suspension e à centre Insertion de support de su...

Страница 7: ...er au besoin avec de l eau ou un détergent neutre REMARQUE Éloigner tous les composants électriques de l eau Ne pas utiliser de produits chimiques corrosifs ou d eau à une température supérieure à 60 ºC 140 F pour nettoyer les pièces en plastique Pour la combinaison ventilateur à éclairage Pour les unités à ventilateur seulement Spécifications du ventilateur Modèle Consommation d énergie W Débit d...

Страница 8: ...0048 Industrial Blvd Lenexa KS 66215 Téléphone 800 747 1762 913 752 6000 Télécopieur 800 487 9915 913 752 6466 www fantech net info fantech net Canada 50 Kanalflakt Way Bouctouche NB E4S 3M5 Téléphone 800 565 3548 506 743 9500 Télécopieur 877 747 8116 506 743 9600 www fantech net info fantech net La présente garantie ne s applique pas à tout produit ou pièce FANTECH INC qui a subi une défaillance ...

Страница 9: ...limentación deben realizarse con cables calibre 14 AWG o más gruesos aptos para al menos 90 C 13 No apto para uso externo 14 En las unidades con luces utilice únicamente una lámpara CFL tipo T4 de 26 W y una lámpara de noche de 4 W como máximo 15 El extractor no debe instalarse en un cielo raso con una calificación R de más de 40 16 El extractor es del tipo IC protección inherente 17 Para reducir ...

Страница 10: ...eación de cada ménsula en las viguetas NOTA El borde inferior de la carcasa debe estar al ras de la parte inferior de la vigueta Figura 4 4 Retire la carcasa e introduzca parcialmente los tornillos en las viguetas en las ubicaciones marcadas Figura 5 ierta de caja conexiones Barra para colgar l Insertar ménsula de suspensión Figura 3 1 Figura0 3 2 Enchufar Figura 5 s Cubierta de caja de conexiones...

Страница 11: ...sa extraiga el motor y luego lávelas con agua o con un detergente neutro según sea necesario NOTA Mantenga todos los componentes eléctricos lejos del agua No utilice productos químicos corrosivos ni agua a más de 60 C 140 F para limpiar las piezas de plástico Para la combinación de extractor con luces Para extractores únicamente Especificaciones del extractor Modelo Consumo de energía W Flujo de a...

Страница 12: ... 66215 Teléfono 800 747 1762 913 752 6000 Fax 800 487 9915 913 752 6466 www fantech net info fantech net Canadá 50 Kanalflakt Way Bouctouche NB E4S 3M5 Teléfono 800 565 3548 506 743 9500 Fax 877 747 8116 506 743 9600 www fantech net info fantech net Esta garantía no se aplica a ningún producto o pieza de FANTECH INC que haya fallado como resultado de una instalación defectuosa o uso indebido conex...