Содержание EPD150LR

Страница 1: ...che NB E4S 3M5 Tel 800 565 3548 Fax 877 747 8116 EPD Series Industrial Dehumidifier Deshumidificador industrial Industrial Dehumidifier Déshumidificateur industriel Deshumidificador industrial Operating Instructions Guide d utilisation Instrucciones de uso Read and Save These Instructions Lisez et conservez ces instructions Lea y guarde estas instrucciones 1 3 5 405037 Fantech Ltd 1 800 565 3548 E...

Страница 2: ...cte a un contacto de pared de conexión a tierra de 3 terminales No quite la terminal de conexión a tierra No use un adaptador No use un cable elétrico de extensión No seguir estas instrucciones puede ocasional la muerte incendio o choque eléctrico ADVERTENCIA El deshumidificador utiliza un sistema de líquido refriger ante de alta presión y un circuito eléctrico de alto voltaje que podrían resultar...

Страница 3: ...te forming on the coil The unit will stay in run mode for variable length of time depending on the ambient conditions Pressing the power button figure 1 will send the unit in shut down mode see below Defrost Mode During the defrost mode the indicator light will turn on figure 2 the compressor will be off and the fan will continue to run The pump purge will be activated automatically The defrost cy...

Страница 4: ...ff by pressing the power button When the dehumidifier is started the hour meter will display the cumulative hours Pump Purge Button Fig 2 In normal operation the pump will automat ically empty the reservoir Pressing this but ton allows manual emptying of the reservoir Press once and the pump will operate for 20 seconds Press and hold the button and the pump will activate for 30 seconds Always manu...

Страница 5: ... area Is the unit being run off a generator Check output does not fluctuate as the unit will not operate at low voltage If using an extension cord Is the cord of the correct gauge for the distance run 14 AWG up to 25 and 12 AWG over 25 Note Verify voltage while unit is starting Start up will cause the highest current draw and largest voltage drop Even if plugged directly to outlet there can be a s...

Страница 6: ... E2 E3 E1 E5 E4 J1 J3 COMPRESSOR O L C R S CONDENSATE PUMP CAPACITOR BLOWER 14uF BLOWER WHITE THERMISTOR FLOAT CAPACITOR COMPRESSOR 60uF BLUE BROWN BLACK BROWN WHITE 2 78119 001 REV 01 WHITE BLACK BLUE BLUE WHITE BLACK WHITE BROWN BLACK RED WHITE WHITE J2 SWITCH PRESSURE ...

Страница 7: ...o apagado inmediatamente Modo de funcionamiento Durante el modo de funcionamiento el compresor está funcionando lo que hace que se enfríe el evaporador dando como resultado la formación de condensación en la bobina La unidad permanecerá en modo de funcionamiento durante una cantidad variable de tiempo dependiendo de las condiciones ambientales Si se pulsa el botón de encendido figura 1 se enviará ...

Страница 8: ...on Fig 1 The dehumidifier is turned on or off by pressing the power button When the dehumidifier is started the hour meter will display the cumulative hours Pump Purge Button Fig 2 In normal operation the pump will automat ically empty the reservoir Pressing this but ton allows manual emptying of the reservoir Press once and the pump will operate for 20 seconds Press and hold the button and the pu...

Страница 9: ...refrigerant system and high voltage circuitry which could present a health hazard resulting in death serious bodily injury and or property damage Only qualified service people should service this unit CAUTION Do not operate unit without the front hood secured in place The serial data plate is located on the underside of the dehumid ifier For service information contact 1 800 565 3548 2 Figure 8 Ca...

Страница 10: ...stá sucio u obstruido Límpielo o sustitúyalo La bobina está sucia Límpiela Conexiones eléctricas flojas o defectuosas hacia el interruptor de presión Verifique las conexiones El ventilador no funciona Sustitúyalo Interruptor de presión defectuoso Sustitúyalo La unidad se congela continuamente Tenga en cuenta que es normal la acumulación de cierta cantidad de hielo en el evaporador pero no debe blo...

Страница 11: ... J3 COMPRESSOR O L C R S CONDENSATE PUMP CAPACITOR BLOWER 14uF BLOWER WHITE THERMISTOR FLOAT CAPACITOR COMPRESSOR 60uF BLUE BROWN BLACK BROWN WHITE 2 78119 001 REV 01 WHITE BLACK BLUE BLUE WHITE BLACK WHITE BROWN BLACK RED WHITE WHITE J2 SWITCH PRESSURE Diagrama de cableado ...

Страница 12: ...anty form and retain it in the event warranty service is required 4 Proof of purchase date will be required for warranty claims Please retain bills of sale for proof 5 Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives specific legal rights and the purchaser may have other rights ...

Страница 13: ...arantía y conservarlo para poder utilizarlo en caso de que sea preciso dar servicio al producto 4 Para cualquier reclamación de garantía será preciso contar con una prueba de compra con fecha Recuerde guardar el recibo como comprobante de venta 5 En algunos estados no se permite la exclusión o limitación de daños consecuentes o secundarios en estos casos la limitación anterior podría no aplicar a ...

Страница 14: ...14 fantech NOTES ...

Страница 15: ...15 fantech NOTAS ...

Страница 16: ...technical changes For updated documentation please refer to www fantech net Fantech Fantech se reserva el derecho de hacer modificaciones técnicas en cualquier momento Para obtener la documen tación actualizada por favor consulte www fantech net ...