13
CONTROL PANEL OPERATION
DIAGNOSTIC LCD MESSAGE
Message Meaning
Action Required
No message on display.
Power has been cut off to the spa.
The control panel will be disabled until power
returns. Spa settings will be preserved until next
power up.
- -
Temperature unknown.
After the pump has been running for 2 minutes,
the temperature will be displayed.
HH
“Overheat” – The spa has shut
down. One of the sensors has de-
tected 118ºF at the heater.
DO NOT ENTER THE WATER. Remove the
spa cover and allow water to cool. Once the
heater has cooled reset by pushing any button.
If spa does not reset, shut off the power to the
spa and call Customer Service.
OH
“Overheat” – the spa has shut down.
One of the sensors has detected
that the spa water is 110ºF.
DO NOT ENTER THE SPA. Follow same
instructions as above.
IC
“Ice” – Potential Freeze condition
detected.
No action required. The pump will automatically
activate regardless of spa status.
SA
Spa is shut down – The sensor that
is plugged into the Sensor “A” jack is
not working.
If the problem persists, contact Customer
Service. It may appear temporarily in an
overheat situation and disappear at cool.
Sb
Spa is shut down. The sensor that
is plugged into the Sensor “B” jack is
not working.
If the problem persists, contact Customer
Service. It may appear temporarily in an
overheat situation and disappear at cool.
Sn
Sensors are out of balance. If
alternating with spa temperature, it
may just be a temporary condition. If
flashing by itself, spa is shut down.
If problem persists, contact Customer Service.
HL
A significant difference between
temperature sensors has been
detected. This could indicate a flow
problem.
Check water level in spa. Refill if necessary. If
the water level is okay, make sure the pumps
have been primed. If problem persists, contact
Customer Service.
LF
Persistent low flow problem (Dis-
plays on the fifth occurrence of “HL”
message within 24 hours.) Heater is
shut down, but other spa functions
continue to run normally.
Follow action required for “HL” message.
Heating capability of the spa will not reset
automatically; you may press any button to
reset.
Dr
Possible inadequate water, poor
flow, or air bubbles in detected in
the heater. Spa is shut down for 15
minutes.
Check water level in spa. Refill if necessary. If
water level is okay, make sure the pumps have
been primed. Press any button to reset, or
this message will automatically reset within 15
minutes. If problem persists, contact Customer
Service.
dY
Inadequate water detected in heater
(Displays on third occurrence of “Dr”
message.) Spa is shut down.
Follow actions required for “Dr” message. Spa
will not automatically reset. Press any button to
reset.