FANN EkoTreat Max WiFi – Installation instructions
5
Settings
Navigation between the diff erent settings is made with
and .
To change a setting:
1.
Hold in until you see a blinking light > and < appears
in the display.
2.
You can then change the setting with and .
3.
Release to save the setting and return to navigation.
Commissioning
Before the unit goes into service, the clock and number of
people in the household need to be set.
Test
Keeping and pressed in at the same time, tests the
water valve and pump.
Sleep
If the drain is not going to be used for a while, the unit can
be put into sleep mode, when no dispensing will be done.
You put the unit in sleep mode by pressing and holding
it for 10 seconds until the display dims. The function light
and alarm light blink during sleep mode. Any alarms will be
reset. To start the unit, press and hold in for 3 seconds,
the display will then be illuminated and the function light
will stay permanently on.
People
To enter the number of people, go to PEOPLE by pressing
and then press in and change the number of people
with . Release both buttons and wait 5 seconds until you
hear a short pip that confirms the new setting.
Set the number of people in the household to ensure the
correct dosage of flocculant.
Set Time and Time zone
To set the clock, go to SET TIME by pressing and holding
it and until the correct time is shown in the display.
Release both buttons and wait 5 seconds until you hear a
short pip that confirms the new setting.
In the event of a brief power outage, the clock will continue
to run, but if the unit has been powerless for a long period,
the clock will need to be reset. If the unit is connected
to the Internet, the time is set automatically for the time
zone specified by the Time zone settings. If the unit is not
connected to the Internet, you can set the clock manually
using the Set time function. Set the Time Zone to Manual
if you prefer to set the time manually when the unit is
connected to the Internet.
WiFi connection
The unit has a WiFi connection for changing the setting
and for viewing the status from a computer, phone or other
internet connected device via
www.fannconfig.se
.
The unit automatically connects to the following WiFi
networks:
1.
The network that was entered via
www.fannconfig.se
2.
Open network without password
3.
Network with password
fann12345
irrespective of
name of network
The blue light will illuminate when the unit is connected to
the Internet. Use the serial number and password supplied
with your unit to log in to
www.fannconfig.se
Factory reset
Use the Factory reset function to reset the unit to its default
settings. Set the setting to Reset on start-up. Wait a few
seconds until the setting is saved. The unit usually returns to
displaying the time, but if the unit has sent an error code, an
error message will appear instead. Disconnect the power to the
unit and wait until the lights stop blinking. Turn on the power
again, and the unit will now be reset to the default settings.
Advanced mode
Additional settings will be displayed if Advanced Mode is
set to On. Advanced settings should only be used in consul-
tation with FANN technical support. Once Advanced Mode
is set to Off , all advanced settings return to default settings.
Alarm sensor
The unit has a flow sensor that automatically detects when
the drum is empty. If the time has been changed, or if a
test has been run immediately before a scheduled dosage,
the sensor will not be read and an alarm warning you of an
empty drum will not be sent, even if the drum is empty. When
the flow sensor takes a reading, the BUSY text will appear on
the display. You cannot change the settings during this time.
In the event of an alarm from the flow sensor, the unit will
continue to try to dispense water and flocculant as per usual.
Alarm reset
If the unit has an active alarm, this can be reset by holding
in for 5 seconds until the display shows Warnings
cleared, when you can release the button.
External LED
An external LED can be connected to provide a clearer light
signal in the event of a fault. Only LEDs with product code
3984 from FANN should be used.
The unit uses encryption when communicating with
www.fannconfig.se
to prevent unauthorised access
to data and passwords.
!
Warnings:
• The pressure from the water pipe must not exceed 8 bar
• Always check that all the connections have been
tightened.