background image

8. TROUBLESHOOTING

7. PARTS BREAKOWN - CONTINUED

PROBLEM

CAUSE

SOLUTION

Motor does not start

E1 displayed on the 

screen

No power or low voltage

Check power supply & 

voltage
Check fuse & replace if 

necessary

Faulty or damaged power 

cord

Check & replace

Faulty motor/capacitor

Check & if necessary replace

Lock-out mode due to 

previous overheating

Detect the cause of 

overheating. Shut the heater 

down. Check air inlet & 

outlet. Wait 5 minutes & 

restart the heater.

E2 displayed on the 

screen

The temperature probe is 

faulty or the connector is 

loose

Check & replace

Check & replace PCB if 

needed

Motor runs but the 

heater does not ignite 

& locks out after a short 

time.

E1 displayed on the 

screen

Empty fuel tank, dirty or 

wrong fuel

Check fuel level, fill the tank 

with clean diesel or kerosene 

if required. Remove wrong or 

dirty fuel.

Fuel filters clogged

Clean or replace fitlers

Air leaks in fuel line

Check fuel lines, connections 

are tight, no cracks. Replace 

if required

Fuel Nozzle clogged

Clean nozzle by blowing 

compressed air or replace if 

required

Fuel viscosity increased at 

low temperature

Blend diesel with kerosene

Flame comes out of 

body

E1 displayed on the 

screen

Insufficient air flow into 

combustion chamber

Check air pump, air inlet, fan 

& motor

Air pressure too high

Check air pump pressure

Heater stops during 

operation

Ambient temperature 

displayed on the screen

The room temperature set 

has been acheived

Adjust the thermostat control 

knob clockwise for higher 

setting

Heater stops during 

operation

E1 displayed on the 

screen

Flame failure

Check & remove the 

cause(s) of the malfunction 

Reset, turn the ON/OFF 

switch to 0 and then again 

to I.

Bad combustion
Reduced air flow

Overheating

Содержание IDH2-20

Страница 1: ...ION MANUAL MODEL IDH2 20 IDH2 30 IDH2 50 INDUSTRIAL DIESEL FAN HEATER DIRECT FIRED TO PREVENT SERIOUS INJURY READ UNDERSTAND ALL WARNINGS INSTRUCTIONS BEFORE USE PLEASE KEEP THIS DOCUMENT FOR YOUR RECORDS FOR INDUSTRIAL USE ONLY ADEQUATE VENTILATION REQUIRED ...

Страница 2: ...make no warranty or representation for any particular purposes The information is offered in good faith and with the understanding that any use of the units or accessories in breach of the directions and warnings in this document is at the sole discretion and risk of the user Disposal Guidelines Do not dispose of this product with general household waste This product must be disposed according to ...

Страница 3: ...ES SUCH AS BUILDING MATERIALS PAPER OR CARDBOARD A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE INSTRUCTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES OR PRODUCTS SUCH AS GASOLINE SOLVENTS PAINT THINNER DUST PARTICLES OR UNKNOWN CHEMICALS DIRECT FIRED HEATERS MAY CAUSE CARBON MONOXIDE CO POISONING WHEN INCORRECTLY USED E G INDOORS WITHOUT ...

Страница 4: ... 9 2 8 4 7 Fuel Nozzle Size gph 0 50 0 80 1 20 Voltage V Hz AC220 240V 50 AC220 240V 50 AC220 240V 50 Air Pressure Setting bar 0 32 0 31 0 38 Current Rating A 1 1 1 1 1 5 Electrical Power W 230 230 340 Fuse Rating T3 15A T3 15A T3 15A Net Weight kg 14 21 27 Dimensions mm 750 L 315 W 415 H 880 L 456 W 590 H 1090 L 490 W 585 H Tank Capacity L 19 38 56 Operating Range H 10 13 12 Standard Accessories ...

Страница 5: ... M12 2 H Wheels 2 I Plain Washer 12 2 J Wheel Shaft 1 K Cotter Pin 2 Fig 2 To assemble the heater proceed as follows see Fig 2 1 Insert the wheel shaft J to the corresponding holes of the feet pipe assembly E 2 Insert the cotter pin K to the corresponding holes Put plain washer I to the two sides of the shaft slide the wheel H over the wheel shaft screw the nut G to fix the wheel on the shaft 3 Pu...

Страница 6: ...t can tip over Keep the heater away from flammable combustible explosive or corrosive materials Keep the heater away from curtains or similar materials that could block the air inlet and outlet Never block or restrict the air inlet and outlet for any reason Keep the power cable away from heat sources sharp edges cutting and moving parts Do not expose directly to the weather or to excessive humidit...

Страница 7: ...t IDH2 50 The left display will show the right display will show the ambient temperature Push the power switch to ON The default temperature setting is 20 C left display If the ambient temperature is lower than the default temperature the electrodes will start sparking after 7 seconds the heater will start If the ambient temperature is higher than the default temperature turn the thermostat contro...

Страница 8: ... NOT reset the heater SHUTDOWN Move switch to OFF O position Never disconnect the heater from mains to stop it while in operation Always allow the cooling sequence to be completed otherwise the residual heat could damage internal components Do not cover the heater Do not block the air inlet and outlet The heater outlet is very hot during operation and after use Do not touch Use personal protecting...

Страница 9: ...ge wetted with lukewarm water and a mild detergent then dry using a clean cloth Keep air inlet and fan free from dust and dirt To clean inner parts gently blow compressed air through air inlet Regularly inspect the power cable if worn cracked or damaged have it replaced by a qualified persons only Before storing the heater make sure it is perfectly cool and dry Cover the unit with a blanket or tar...

Страница 10: ...asuring port on the rear guard Start heater and read air pressure value If necessary adjust pressure to the correct value turning the adjusting screw the air vent hole in the adjusting screw middle clockwise to increase anticlockwise to decrease the pressure Ignition Electrodes qualified perons only Clean adjust if necessary replace ignition electrode For electrode gaps see Fig 4 5 dimensions in m...

Страница 11: ...6 WIRING DIAGRAM WIRING DIAGRAM IDH2 20 IDH2 30 WIRING DIAGRAM IDH2 50 ...

Страница 12: ...7 PARTS BREAKDOWN IDH2 20 ...

Страница 13: ...7 PARTS BREAKDOWN CONTINUED IDH2 30 ...

Страница 14: ...7 PARTS BREAKOWN CONTINUED IDH2 50 ...

Страница 15: ... diesel or kerosene if required Remove wrong or dirty fuel Fuel filters clogged Clean or replace fitlers Air leaks in fuel line Check fuel lines connections are tight no cracks Replace if required Fuel Nozzle clogged Clean nozzle by blowing compressed air or replace if required Fuel viscosity increased at low temperature Blend diesel with kerosene Flame comes out of body E1 displayed on the screen...

Страница 16: ...ng a mult meter check both ends of thermostat If there is a resistance value showing the thermostat is working If there is no resistance replace thermostat 3 Photocell break down Check Photocell assembly Pull out the photocell let it sense light Using a multi meter connect both ends if there is no resistance showing the photocell is good If there is a resistance replace ...

Страница 17: ...i meter check motor circuit 5 Air Line Leakage Check Air Line Take out the air line Carefully check the line surface Replace if there are any cracks or damages 6 Fuel Filters Blocked Check Fuel Filters Tale out the fuel filter If blocked clean it out then rinse soak in diesel or kerosene If blockage is too thick replace fuel filter ...

Страница 18: ...e air pump is good If it fails to reach this point replace air pump Factory setting is 5 6 PSI 8 Fuel Nozzle Blocked Check Clean the nozzle If there is black smoke or flash fire check clean fuel nozzle if the same symptoms keep occuring replace the fuel nozzle 9 Prob damage E2 Check probe Open the control panel check the condition of the probe connection point If the probe end is damaged replace i...

Страница 19: ... cannot be excluded under the Australian Consumer Law You are entitled to replacement or refund for a major failure and to compensation for other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure Exclusions This warranty does not cover Any defects caused...

Страница 20: ...N11664 MADE IN CHINA Fanmaster Pty Ltd 1 6 8 Yalgar Road KIRRAWEE NSW 2232 1300 900 345 sales fanmaster com au www fanmaster com au FANMASTER cooling heating ventilation extraction ...

Отзывы: