background image

Collar

4

Electrical and Structural Requirements

Ceiling

Ceiling

Joists

2

˝

 x 4

˝

Outlet

Box

Figure 1

How to Assemble Your Down Rod Sleeve

Collar (2)

Sleeve, 8

˝

Checkring

Figure 1

1. 

Prior to assembly, set aside and save the hardware 

bag(s) packed in the packing.

2. 

Check to see that you have received the following parts 

(Figure 1).

Figure 2

WARNING

To avoid fire or shock, follow all wiring instructions 

carefully.  Any electrical work not described in these 

instructions should be done or approved by a licensed 

electrician.

If your fan is to replace an existing light fixture, turn 
electricity off at the main fuse box at this time and remove 
the existing light fixture.

WARNING

Turning off wall switch is not sufficient.  To avoid 

possible electrical shock, be sure electricity is turned 

off at the main fuse box before wiring.  All wiring must 

be in accordance with National and Local codes and the 

ceiling fan must be properly grounded as a precaution 

against possible electrical shock.

WARNING

To reduce the risk of fire, electrical shock, or personal 

injury, mount fan to outlet box marked acceptable 

for fan support of 22.7 kg (50 lbs) or less. Use screws 

supplied with outlet box.  Most outlet boxes commonly 

used for support of light fixtures are not acceptable for 

fan support and may need to be replaced.  Consult a 

qualified electrician if in doubt.

Your new ceiling fan will require a grounded electrical 
supply line of 120 volts AC, 60 Hz, 15 amp circuit.  The 
outlet box must be securely anchored and capable of 
withstanding a load of at least 22.7 kgs (50 lbs).  

Figure 1

 

depicts different structural configurations that may be used 
for mounting the outlet box.

Sleeve, 4

˝

DR1x6

6

˝

 Down Rod Assembly:

3. 

Assemble one Collar with allen wrench provided, as 

shown (Figure 2).

NOTE: 

 You will be using either the 6

˝

 downrod supplied with 

your fan or an optional downrod purchased separately.

INSTALLATION NOTE

For various Downrod lengths, maintain the distance 

between 2½ to 3½ from the bottom of Collar to the end of 

Downrod as shown.

˝

Содержание HF7000 Series

Страница 1: ...3 lbs WARNING Support Directly From Building Structure For Canada this fan must be secured directly to the building structure or ceiling joist Don t secure this fan to an outlet box Acharn Fan Net Wei...

Страница 2: ...eaning unit switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked secu...

Страница 3: ...r One wire stripper Three wire connectors supplied Ceiling Canopy WARNING Do not install or use fan if any part is damaged or missing This product is designed to use only those parts supplied with thi...

Страница 4: ...be properly grounded as a precaution against possible electrical shock WARNING To reduce the risk of fire electrical shock or personal injury mount fan to outlet box marked acceptable for fan support...

Страница 5: ...gure 3 Collar Figure 4 DR1x18 18 Down Rod Assembly 4 Assemble the 18 Down Rod and the Sleeve Kit in the order as shown Figure 4 Sleeve 4 Collar Figure 5 DR1x24 or Longer 24 or longer Down Rod Assembly...

Страница 6: ...bly on styrofoam for ease of assembly 5 Loosen the two setscrews in the Downrod Support Align the Clevis Pin holes in the Downrod with the holes in the Downrod Support Install the Clevis Pin and secur...

Страница 7: ...Hanger Ball Assembly Figure 6 Downrod Support Figure 5b Figure 5a 8 The three screws are pre assembled onto the Fan Motor assembly Figure 4 Remove three screws and use them to attach the Housing Fixtu...

Страница 8: ...s omitted for clarity 1 Using the 3 8 x 2 lag bolt and flat washer attach safety cable to ceiling joist or wood structural member The lag bolt will pass through the flat washer safety cable loop the j...

Страница 9: ...cover off Slide code switches to your choice of up or down position Factory setting is all up Do not use this position With a small screwdriver or ball point pen slide firmly up or down Figure 1a Rep...

Страница 10: ...ng the Fan Blades 1 Lay blade holder with the threaded posts facing up 2 Position the wood blade over the blade holder with the threaded posts showing through the holes of the blade 3 With a Phillips...

Страница 11: ...the Receiver Unit and Switch Cup Housing NOTE This step is applicable for model without lower Light Kits For Acharn or Scroll fan models skip this section and go to page 14 or 16 Figure 2 IMPORTANT A...

Страница 12: ...Downrod Assembly ADR1x6 3 Downrod Cover Assembly AP7070 4 Ceiling Canopy P7080 7 Fan Motor Assembly AMA7000 8 Blade Holder Set 5 AP7030 9 Wood Blade Set 5 Coffee or Slate AP7052 10 Switch Cup Cover As...

Страница 13: ...13 NOTE The illustration shown is not to scale or its actual configuration may vary Decorative Uplight Fan HF7040 Exploded View also for Acharn Scroll Fans 4 1 Figure 1 3 6 5 2 7 13 12 11 8 9 10...

Страница 14: ...fixture unit on switch cup cover with lockwasher and nut provided 3 Locate white and blue wires labeled FOR LIGHT Securely connect white to white and blue to black wires as shown Push the connectors u...

Страница 15: ...assembly WARNING Check to see that all connections are tight To avoid possible electrical shock make sure that the wires are completely inside the switch cup housing and not pinched between the housin...

Страница 16: ...ngle light fixture unit on switch cup cover with lockwasher and nut provided CAUTION To avoid possible electrical shock be sure electricity is turned off at the main fuse box before installing light k...

Страница 17: ...cont d WARNING Check to see that all connections are tight To avoid possible electrical shock make sure that the wires are completely inside the switch cup housing and not pinched between the housing...

Страница 18: ...ht 2 Check to make sure wire connectors in switch housing are not rattling against each other or against the interior wall of the switch housing CAUTION Make sure main power is turned off 3 Some fan m...

Страница 19: ......

Страница 20: ...ION 10983 Bennett Parkway Zionsville IN 46077 888 567 2055 FAX 866 482 5215 Outside U S call 317 733 4113 Visit Our Website www fanimation com All Hubbardton Forge designs the mark HUBBARDTON FORGE an...