How to Hang Your Ceiling Fan

Figure 1

Floor

No

less than

7 ft

WARNING

The fan must be hung with at least 7´ of clearance from 

floor to blades (Figure 1)

WARNING

The outlet box must be securely anchored and capable 

of withstanding a load of at least 50 lbs.  Hanger bracket 

must seat firmly against outlet box.  If the outlet box is 

recessed, remove wallboard until bracket contacts box.  

If bracket and/or outlet box are not securely attached, 

the fan could wobble or fall.

WARNING

Failure to seat tab in groove could cause damage to 

electrical wires and possible shock or fire hazard.

WARNING

To avoid possible shock, do not pinch wires between the 

downrod/hanger ball assembly and the hanger bracket.

WARNING

To avoid possible electrical shock, be sure electricity is 

turned off at the main fuse box before hanging.

NOTE: If you are not sure if the outlet box is grounded, 

contact a licensed electrician for advice, as it must be 

grounded for safe operation.

Ceiling Joist

Wood  Member

(2

˝

 x 4

˝

 Approx.)

Figure 2

Junction 

Box

Ceiling

Support

Cable

Hanger Bracket

Ceiling

Figure 3

Downrod/Hanger

Ball Assembly

Attach

Safety Cable to

Ceiling Support

Cable

Tab

NOTE: 

Supply wires and

fan wires omitted for clarity

1.

  Using the 

3

8

˝

 x 2

˝

 lag bolt and flat washer, attach 

safety cable to ceiling joist or wood structural member. 

The lag bolt will pass through the flat washer, safety 

cable loop, the junction box and into the building structure 

(Figure 2). You will first drill a ¼

˝

 pilot hole into the 

building structure to prevent splitting or cracking.

2.

  Securely attach the hanger bracket to ceiling junction 

box 

acceptable for ceiling support

NOTE:

 

 Ceiling support cable cannot be secured to 

junction box only, it must be directly secured to ceiling 

joist or structural member 

using the 

˝

 x 2

˝

 lag bolt and 

fl

 at washer.

  (Figure 2).

3.

  Make sure the electrical supply wires, including the 

hanger bracket grounding wire and safety cable are 

pulled through the downrod, between the hanger bracket 

and the junction box so that electrical connections can be 

made later. 

4.

  Carefully lift the fan and seat the downrod/hanger ball 

assembly on the hanger bracket that was just attached to 

the ceiling joist.  Be sure the groove in the ball is lined up 

with tab on the hanger bracket. (Figure 3)

5.

  Attach the safety cable to ceiling support cable. Slide 

cable clamp onto safety cable (from fan). Place the end 

of cable through the loop of ceiling support cable. Pull as 

much cable through loop as possible. Feed end of cable 

into clamp hole and firmly tighten screw (Figure 3).  Cut 

off excess safety cable.

Содержание HF7000 Series

Страница 1: ...3 lbs WARNING Support Directly From Building Structure For Canada this fan must be secured directly to the building structure or ceiling joist Don t secure this fan to an outlet box Acharn Fan Net Wei...

Страница 2: ...eaning unit switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked secu...

Страница 3: ...r One wire stripper Three wire connectors supplied Ceiling Canopy WARNING Do not install or use fan if any part is damaged or missing This product is designed to use only those parts supplied with thi...

Страница 4: ...be properly grounded as a precaution against possible electrical shock WARNING To reduce the risk of fire electrical shock or personal injury mount fan to outlet box marked acceptable for fan support...

Страница 5: ...gure 3 Collar Figure 4 DR1x18 18 Down Rod Assembly 4 Assemble the 18 Down Rod and the Sleeve Kit in the order as shown Figure 4 Sleeve 4 Collar Figure 5 DR1x24 or Longer 24 or longer Down Rod Assembly...

Страница 6: ...bly on styrofoam for ease of assembly 5 Loosen the two setscrews in the Downrod Support Align the Clevis Pin holes in the Downrod with the holes in the Downrod Support Install the Clevis Pin and secur...

Страница 7: ...Hanger Ball Assembly Figure 6 Downrod Support Figure 5b Figure 5a 8 The three screws are pre assembled onto the Fan Motor assembly Figure 4 Remove three screws and use them to attach the Housing Fixtu...

Страница 8: ...s omitted for clarity 1 Using the 3 8 x 2 lag bolt and flat washer attach safety cable to ceiling joist or wood structural member The lag bolt will pass through the flat washer safety cable loop the j...

Страница 9: ...cover off Slide code switches to your choice of up or down position Factory setting is all up Do not use this position With a small screwdriver or ball point pen slide firmly up or down Figure 1a Rep...

Страница 10: ...ng the Fan Blades 1 Lay blade holder with the threaded posts facing up 2 Position the wood blade over the blade holder with the threaded posts showing through the holes of the blade 3 With a Phillips...

Страница 11: ...the Receiver Unit and Switch Cup Housing NOTE This step is applicable for model without lower Light Kits For Acharn or Scroll fan models skip this section and go to page 14 or 16 Figure 2 IMPORTANT A...

Страница 12: ...Downrod Assembly ADR1x6 3 Downrod Cover Assembly AP7070 4 Ceiling Canopy P7080 7 Fan Motor Assembly AMA7000 8 Blade Holder Set 5 AP7030 9 Wood Blade Set 5 Coffee or Slate AP7052 10 Switch Cup Cover As...

Страница 13: ...13 NOTE The illustration shown is not to scale or its actual configuration may vary Decorative Uplight Fan HF7040 Exploded View also for Acharn Scroll Fans 4 1 Figure 1 3 6 5 2 7 13 12 11 8 9 10...

Страница 14: ...fixture unit on switch cup cover with lockwasher and nut provided 3 Locate white and blue wires labeled FOR LIGHT Securely connect white to white and blue to black wires as shown Push the connectors u...

Страница 15: ...assembly WARNING Check to see that all connections are tight To avoid possible electrical shock make sure that the wires are completely inside the switch cup housing and not pinched between the housin...

Страница 16: ...ngle light fixture unit on switch cup cover with lockwasher and nut provided CAUTION To avoid possible electrical shock be sure electricity is turned off at the main fuse box before installing light k...

Страница 17: ...cont d WARNING Check to see that all connections are tight To avoid possible electrical shock make sure that the wires are completely inside the switch cup housing and not pinched between the housing...

Страница 18: ...ht 2 Check to make sure wire connectors in switch housing are not rattling against each other or against the interior wall of the switch housing CAUTION Make sure main power is turned off 3 Some fan m...

Страница 19: ......

Страница 20: ...ION 10983 Bennett Parkway Zionsville IN 46077 888 567 2055 FAX 866 482 5215 Outside U S call 317 733 4113 Visit Our Website www fanimation com All Hubbardton Forge designs the mark HUBBARDTON FORGE an...

Отзывы: