background image

Reverse Switch Information

Season

Rotation Direction

Switch Position

Summer

Counter-Clockwise

Left

Winter

Clockwise

Right

5.

 If airflow is desired in the opposite direction, turn the 

fan off and wait for the blades to stop turning. Slide the 
reverse switch on top of motor assembly to the 
opposite position and turn fan on again. (Figure 5)

Figure 5

Reversing
Switch

 

4.

 

Pairing Process for Receiver & Transmitter:

 

(Figure 4)
– The receiver and accompanying transmitter are 
matched at the factory. If replacing transmitter or 
receiver, you must follow the pairing process below 
before using the unit. The fanSync receiver can be
paired to up to five (5) transmitters. 
NOTE: Smart device pairing is unlimited.
–  After installing the receiver unit, set desired 
transmitter code by pushing dip switches (under 
battery cover) up or down to the desired positions. 
Once code is set, restore power to your fan and press 
and hold the fan off button (    ) for approximately 1 to 3 
seconds. Fan will turn off, then turn on to medium 
speed to indicate that the pairing process is complete. 
Please note that you must press the fan off button (    ) 
within 30 senconds after restoring power. Re-pairing 
your device is not necessary after replacing the battery. 
Each fanSync receiver can pair to five different 
transmitters (with different dip switch codes).

CR2430  3V 

21',3

Dip Switch

Dimmer Switch

DIMMER

ON/OFF

NOTE:

 Transmitters can pair to multiple receivers, when 

performing the pairing process take care not to pair the 
transmitter to unintended receivers. It is suggested that 
fans more than seven feet apart be on separate power 
switches.

How to Operate Your Remote Control 

(continued)

14

       

       

 

       : Turns off ceiling fan.     
       : Turns on ceiling fan to high speed     
       : Turns on ceiling fan to medium speed  
       : Turns on ceiling fan to low speed 

NOTE: To use your smart device to control your 
receiver, download the fanSync app from your app 
store. Visit www.fanimation.com/fanSync

3.

 Remote button functions are as follows: (Figure 3)

        

 LIGHT ON/OFF: Press and release button 

immediately to turn light on or off.          

 

         LIGHT DIMMER: Press and hold to dim or 
 

brighten light to desired level and release. 

Figure 3

Figure 4

Содержание FP8062 Series

Страница 1: ...Net Weight 17 86 lbs 8 10 kgs OWNER S MANUAL READ AND SAVE THESE INSTRUCTIONS Model No FP8062 The Celano v2 Ceiling Fan...

Страница 2: ...1 To avoid possible shock be sure electricity is turned off at the fuse box before wiring and do not operate fan without blades 2 All wiring and installation procedures must satisfy National Electric...

Страница 3: ...Hang Your Ceiling Fan How to Wire Your Ceiling Fan Installing Your Canopy Housing 8 10 11 12 7 How to Assemble Your Ceiling Fan Blades How to Operate Your Remote Control 13 How to Install Your Remote...

Страница 4: ...or use fan if any part is damaged or missing This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Fa...

Страница 5: ...draft which forces warm air near the ceiling down into the occupied space Remember to adjust your thermostat when using your ceiling fan additional energy and dollar savings could be realized with thi...

Страница 6: ...een two joists and takes the place of wooden blocking To avoid fire or shock follow all wiring instructions carefully Any electrical work not described in these instructions should be done or approved...

Страница 7: ...igure 3 1 Remove the two preassembled screws of the downrod support from the motor assembly then retain the screws for How to Assemble Your Ceiling Fan Step 4 Figure 1 2 Remove the six preassembled sc...

Страница 8: ...ow to Assemble Your Ceiling Fan Downrod Set Screw Pin Hanger Ball 1 Remove the hanger ball portion from the downrod hanger ball assembly by loosening the set screw in the hanger ball until the ball fa...

Страница 9: ...the downrod Figure 3 Figure 4 Downrod Set Screws and Locking Nuts 2 Hairpin Clip Clevis Pin Figure 3 Black White and Blue wires Figure 7 Motor Coupling Cover Ceiling Canopy Canopy Screw Cover 7 Cut of...

Страница 10: ...ews and washers supplied with the outlet box Figure 3 WARNING The outlet box must be securely anchored Hanger bracket must seat rmly against outlet box If the outlet box is recessed remove wall board...

Страница 11: ...en wires from hanger bracket and hanger ball to bare ground wire using wire connector supplied Connect black wire from receiver unit marked AC IN L to black supply wire using wire connector supplied C...

Страница 12: ...and the ceiling Figure 1 Figure 2 How to Assemble Your Light Kit The light source is designed for this specific application and can overheat if serviced by untrained personnel If any servicing is req...

Страница 13: ...rate fan until the blades are in place Noise and fan damage could result WARNING WARNING Do not operate this fan with a variable Rheostat wall controller or dimmer switch Doing so could result in dama...

Страница 14: ...rn off then turn on to medium speed to indicate that the pairing process is complete Please note that you must press the fan off button within 30 senconds after restoring power Re pairing your device...

Страница 15: ...s i n i f e h t g n i h c t a r c s d i o v a o t Abrasive cleaning agents are not required and should be avoided to prevent damage to finish Periodic light dusting of the blades is recommended A fea...

Страница 16: ...py Screw Cover Assembly APGAC110RBL ADRAC1 45 PPAC1010 APPAC1101 AP1115 AMA8062F 7 10 Light Plate Assembly Light Kit Glass Assembly AP806203 11 Hand Held Remote BTR9 8062PG 12 Receiver HDWFP8062 BTT9...

Страница 17: ...2 3 4 5 6 10 11 7 12 8 9 Model FP8062 Exploded View Illustration Celano v2 NOTE The illustration shown is not to scale or its actual con guration may vary Product parts are subject to change without n...

Страница 18: ...3 Check to make sure the screws which attach the fan blade to the motor assembly are tight 3 Check to make sure the screws which attach the fan blade to the motor assembly are tight CAUTION Make sure...

Страница 19: ...Copyright 2015 Fanimation 2015 12 V 01 10983 Bennett Parkway Zionsville IN 46077 888 567 2055 FAX 866 482 5215 Outside U S call 317 733 4113 Visit Our Website www fanimation com...

Страница 20: ...The Celano v2 Ventilador de techo Peso neto 8 10 kgs 17 86 lbs Modelo N FP8062 MANUAL DEL PROPIETARIO LEA Y GUARDE ESTAS INSTRUCCIONES...

Страница 21: ...ra apoyo de los aficionados PARA REDUCIR EL RIESGO DE DESCARGAS EL CTRICAS ESTE VENTILADOR SE DEBE INSTALAR CON UN CONTROL INTERRUPTOR DE PARED AISLADO ADVERTENCIA Este producto est dise ado para ser...

Страница 22: ...as deber n ir acompa adas del recibo de venta y deber n enviarse a Fanimation previo pago del flete El ventilador que se devuelva deber estar embalado en forma adecuada a fin de evitar da os durante e...

Страница 23: ...iluminaci n Ensamble del kit de iluminaci n el vidrio Juego de aspas Control remoto de mano Unidad del receptor Instrucciones para el desempaque Para su comodidad marque cada uno de los pasos Amedida...

Страница 24: ...tinuaci nlepresentamosalgunassugerencias para asegurar un rendimiento eficiente del producto Selecci n del lugar de montaje adecuado Los ventiladores de techo se deben instalar en el centro de la habi...

Страница 25: ...rgas el ctricas aseg rese de que la electricidad est desconectada en la caja de fusibles principal antes de realizar la instalaci n el ctrica Toda instalaci n el ctrica debe cumplir con los c digos na...

Страница 26: ...de fibra para asegurar el aspa al volante del ensamble del motor Figura 4 C mo ensamblar las aspas del ventilador de techo 2 Retire los seis tornillos preensamblados de la arandela del acoplador del m...

Страница 27: ...dor de techo 2 Retire el clip de horquilla y pasador de horquilla de la parte inferior de la bola para colgar Retener el pasador y clip para la reinstalaci n en el paso 4 Figura 2 1 Extraiga la pieza...

Страница 28: ...n del motor la cubierta para el tornillo y el capuch n Figura 5 Capuch n de techo Cubierta de uni n del motor Cubierta del tornillo de la base 7 Corte el exceso de cable aproximadamente de 15 a 23 cm...

Страница 29: ...olgar y la abrazadera para colgar ADVERTENCIA ADVERTENCIA Para evitar una posible descarga el ctrica aseg rese de cortar la alimentaci n el ctrica de la caja de fusibles principal antes de colgar el v...

Страница 30: ...tor de cables suministrado con el receptor Conecte el cable blanco desde la unidad del receptor marcado TO MOTOR L al cable blanco del ventilador utilizando el conector de cables suministrado con el r...

Страница 31: ...nsamblar las kit de luz Ensamble de la placa de iluminaci n Ensamble de la placa de iluminaci n Figura 2 Unidad del motor Unidad de luz LED PRECAUCI N A fin de reducir el riesgo descargas el ctricas d...

Страница 32: ...cendio o descarga el ctrica no utilice dicho regulador para controlar la velocidad del ventilador Figura 1 2 Restaure la fuente de alimentaci n de la toma de corriente enciendo la electricidad del fus...

Страница 33: ...los interruptores DIP ubicados debajo de la carcasa de la bater a arriba o abajo para colocarlos en la posici n deseada Cuando el c digo haya sido configurado desconecte y vuelva a conectar el ventil...

Страница 34: ...un cepillo suave o un pa o sin pelusas para evitar rayar el acabado No se requieren agentes abrasivos de limpieza los mismos deben evitarse para prevenir da os en el acabado PRECAUCI N No utilice sol...

Страница 35: ...FP8062 1 2 3 4 5 6 Cubierta para el tornillo del capuch n APGAC110RBL ADRAC1 45 PPAC1010 APPAC1101 AP1115 AMA8062F 7 10 Ensamble de la placa de iluminaci n Ensamble del kit de iluminaci n el vidrio AP...

Страница 36: ...36 1 2 3 4 5 6 10 11 7 12 8 9 Model FP8062 Ilustraci n del despiece Celano v2 NOTA OD LOXVWUDFLyQ TXH VH PXHVWUD QR HVWi KHFKD D HV FDOD VX FRQ JXUDFLyQ UHDO SXHGH YDULDU...

Страница 37: ...de la caja del motor est n bien ajustados pero no en exceso 3 Aseg rese de que los tornillos que fijan los soportes de aspas al buje del motor del ventilador est n bien ajustados 3 EL VENTILADOR OSCIL...

Страница 38: ...Copyright 2015 Fanimation 2015 12 V 01 10983 Bennett Parkway Zionsville IN 46077 888 567 2055 FAX 866 482 5215 Outside U S call 317 733 4113 Visit Our Website www fanimation com...

Отзывы: