Energy Efficient Use of Ceiling Fans

Ceiling  fan  performance  and  energy  savings  rely

heavily  on  the  proper  installation  and  use  of  the

ceiling fan. Here are a few tips to ensure efficient

product performance.
Choosing the Appropriate Mounting Location

Ceiling  fans  should  be  installed,  or  mounted,  in  the

middle of the room and at least 7 feet above the floor

and 18 inches from the walls. If ceiling height allows,

install  the  fan  8  -  9  feet  above  the  floor  for  optimal

airflow.  Consult  your  Fanimation  Retailer  for  optional

mounting accessories.

Turn Off When Not in the Room

Ceiling  fans  cool  people,  not  rooms.  If  the  room  is

unoccupied, turn off the ceiling fan to save energy.

Using the Ceiling Fan Year Round
Summer  Season: 

Use  the  ceiling  fan  in  the

counterclockwise  direction.  The  airflow  produced  by

the ceiling fan creates a wind-chill effect, making you

“feel”  cooler.  Select  a  fan  speed  that  provides  a

comfortable  breeze,  lower  speeds  consume  less

energy.

Winter  Season: 

Reverse  the  motor  and  operate  the

ceiling  fan  at  low  speed  in  the  clockwise  direction.

This produces a gentle updraft, which forces warm air

near  the  ceiling  down  into  the  occupied  space.

Remember to adjust your thermostat when using your

ceiling  fan  -  additional  energy  and  dollar  savings

could be realized with this simple step!

Electrical and Structural Requirements

If  your  fan  is  to  replace  an  existing  light  fixture,  turn

electricity  off  at  the  main  fuse  box  at  this  time  and

remove the existing light fixture.

Your new ceiling fan will require a grounded electrical

supply  line  of  120  volts  AC,  60  Hz,  15  amp  circuit.

The  outlet  box  must  be  securely  anchored  and

capable  of  withstanding  a  load  of  at  least  50  lbs.

Figure  1

depicts  different  structural  configurations

that may be used for mounting the outlet box.

To avoid fire or shock, follow all wiring instructions

carefully. Any electrical work not described in these

instructions  should  be  done  or  approved  by  a

licensed electrician.

Turning  off  wall  switch  is  not  sufficient.  To  avoid

possible  electrical  shock,  be  sure  electricity  is

turned  off  at  the  main  fuse  box  before  wiring.  All

wiring  must  be  in  accordance  with  National  and

Local  codes  and  the  ceiling  fan  must  be  properly

grounded as a precaution against possible electrical

shock.

WARNING

WARNING

To  reduce  the  risk  of  fire,  electrical  shock,  or

personal  injury,  mount  fan  to  outlet  box  marked

acceptable for fan support of 

35

lbs (

15

.

88

 kg) or less.

Use  screws  supplied  with  outlet  box.  Most  outlet

boxes  commonly  used  for  support  of  light  fixtures

are not acceptable for fan support and may need to

be  replaced.  Consult  a  qualified  electrician  if

in doubt.

WARNING

Figure 1

CEILING

2" x 4"

CEILING JOIST

OUTLET BOX

Содержание FP8050 The Quattro

Страница 1: ...Model No FP8050 Ceiling Fan OWNER S MANUAL READ AND SAVE THESE INSTRUCTIONS Net Weight 7 3 kgs 16 1 lbs The Quattro ...

Страница 2: ...he defective fan is returned to our national service center Proof of purchase is required Customer shall be responsible for all costs incurred in the removal or reinstallation and shipping of the product for repairs or replacement 2 ONE YEAR MOTOR LABOR WARRANTY If your fan motor fails at any time within one year from the original purchase due to defects in materials or workmanship labor to repair...

Страница 3: ...s product by Fanimation Substitution of parts or accessories not designated for use with this product by Fanimation could result in personal injury or property damage WARNING One wire stripper One 1 4 blade screwdriver Materials Wiring outlet box and box connectors must be of type required by the local code The minimum wire would be a 3 conductor 2 wire with ground of the following size NOTE Place...

Страница 4: ...ollar savings could be realized with this simple step Electrical and Structural Requirements If your fan is to replace an existing light fixture turn electricity off at the main fuse box at this time and remove the existing light fixture Your new ceiling fan will require a grounded electrical supply line of 120 volts AC 60 Hz 15 amp circuit The outlet box must be securely anchored and capable of w...

Страница 5: ...gure 3 4 Route wires through motor coupling cover canopy screw cover and canopy Figure 4 5 Reinstall the hanger ball on the downrod as follows Route the three 80 inch wires through the hanger ball Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball Pull the hanger ball up tight against the pin Securely t...

Страница 6: ...n for advise as it must be grounded for safe operation The outlet box must be securely anchored Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet box are not securely attached the fan could wobble or fall WARNING 2 Carefully lift the fan and seat the downrod hanger ball assembly on the hanger brack...

Страница 7: ...it into the open end of the hanger bracket Figure 4 4 Connect green wires from hanger bracket and hanger ball to bare ground wire using wire connector supplied Connect black wire from receiver unit marked AC IN L to black supply wire using wire connector supplied Connect white wire from receiver unit marked AC IN N to white supply wire using wire connector supplied Connect white wire from receiver...

Страница 8: ...de of the outlet box Figure 6 CANOPY SHOULDER SCREWS 2 Figure 1 CANOPY COVER Figure 2 1 Remove one of the two shoulder screws in the hanger bracket Loosen the second shoulder screw without fully removing it Assemble canopy by rotating key slot in canopy over shoulder screw in hanger bracket Tighten shoulder screw Fully assemble and tighten second shoulder screw that was previously removed Figure 1...

Страница 9: ...ector from the Upper Light Kit Plate to the 2 pin connector from motor assembly Figure 2 3 Assemble the Upper Light Kit Plate to the Housing Support Bracket by aligning key slots in Plate with the two screws in Support Bracket Assemble screw removed in step 2 and tighten all three screws Figure 3 Do not connect fan blades until the fan is completely installed Installing the fan with blades assembl...

Страница 10: ...y turning the electricity on at the main fuse box Figure 1 2 To make fan operational install 9 volt battery in hand held remote transmitter if not using for long periods of time remove battery to prevent damage to transmitter Store the remote away from excessive heat or humidly Figure 2 Check to see that all connections are tight including ground and that no bare wire is visible at the wire connec...

Страница 11: ...n Rotation Direction Switch Position Summer Counter Clockwise Left Winter Clockwise Right 5 BUTTON REMOTE CONTROL Figure 3 Maintenance 1 Periodic cleaning of your new ceiling fan is the only maintenance that is needed When cleaning use only a soft brush or lint free cloth to avoid scratching the finish Abrasive cleaning agents are not required and should be avoided to prevent damage to finish Do n...

Страница 12: ...s are not recommended choose an alternative control method 6 Tighten screws securely 7 Tighten set screw securely 1 Blades not attached to fan 2 Loose screws in motor housing 3 Screws securing fan blade holders to motor flywheel are loose 4 Wire connectors inside housing rattling 5 Motor noise caused by solid state variable speed control 6 Screws holding blades to blade holders are loose 7 Lower h...

Страница 13: ...y Loose Parts Wire Connector 4 Washer Head Screw 3 16 24 x 12 5mm 13 Fiber Washer 3 16 13 1 2 3 4 5 6 7 8 9 10 11 12 13 14 4 Phillips Head Screwdriver AMA8050 APGAC110RBL ADRAC1 45 P805001 APPAC1101 AP1115 AP805005 P805006CH PPGU10B50 AP805008 RECAN44 C24 BALKT HDWFP8050 Parts List 14 Insert FINISH CODE Refer to fan model number located on downrod support HOW TO ORDER REPAIR PARTS When ordering re...

Страница 14: ...Copyright Fanimation 2010 2010 05 10983 Bennett Parkway Zionsville IN 46077 Toll Free 888 567 2055 FAX 866 482 5215 Outside U S call 317 733 4113 Fanimation Visit Our Website www fanimation com ...