Fanimation FP8050 The Quattro Скачать руководство пользователя страница 2

2

Important Safety Instructions

WARNING: 

To avoid fire, shock and serious personal injury, follow these instructions.

1. Read  your  owner’s  manual  and  safety  information  before  installing  your  new  fan.  Review  the  accompanying  assembly

diagrams.

2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent

power  from  being  switched  on  accidentally.  When  the  service  disconnecting  means  cannot  be  locked,  securely  fasten  a
warning device, such as a tag, to the service panel.

3. Be careful of the fan and blades when cleaning, painting, or working near the fan. Always turn off the power to the ceiling

fan before servicing.

4. Do not insert anything into the fan blades while the fan is operating.
5. Do not operate reversing switch until fan blades have come to a complete stop.

Additional Safety Instructions

1. To  avoid  possible  shock,  be  sure  electricity  is  turned  off  at  the  fuse  box  before  wiring,  and  do  not  operate  fan  without

blades.

2. All  wiring  and  installation  procedures  must  satisfy  National  Electrical  Codes  (ANSI/  NFPA  70-1999)  and  Local  Codes.  The

ceiling  fan  must  be  grounded  as  a  precaution  against  possible  electrical  shock.  Electrical  installation  should  be  made  or
approved by a licensed electrician.

3. The  fan  base  must  be  securely  mounted  and  capable  of  reliably  supporting  at  least 

35

  lbs.  (fan  and  accessories  not  to

exceed 

35

  lbs.  or 

15

.

88

  kgs.).  See  page  4  of  owner’s  manual  for  support  requirements.  Consult  a  qualified  electrician  if  in

doubt.

4. The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades.
5. Follow  the  recommended  instructions  for  the  proper  method  of  wiring  your  ceiling  fan.  If  you  do  not  have  adequate

electrical knowledge or experience, have your fan installed by licensed electrician.

6. Suitable for use with solid-state speed controls.

WARNING:

To  reduce  the  risk  of  fire  or  electric  shock,  this  fan  should  only  be  used  with  Fan  Speed  Control  Part  No.

UC7067R

YL

, manufactured by Rhine Electronic Co., Ltd.

WARNING:

TO  REDUCE  THE  RISK  OF 

ELECTRIC 

SHOCK,  THIS  FAN  MUST  BE  INSTALLED  WITH  A

 GENERAL

USE ISOLATING WALL 

CONTROL/SWITCH.

WARNING:

This  product  is  designed  to  use  only  those  parts  supplied  with  this  product  and/or  accessories  designated

specifically for use with this product. Using parts and/or accessories not designated for use with this product could result in
personal injury or property damage.

WARNING: 

To reduce the risk of personal injury, do not bend the blade bracket (flange or blade holder) when installing the

brackets, balancing the blades, or cleaning the fan. Do not insert foreign objects in between rotating fan blades.

LIMITED LIFETIME WARRANTY

Extends to the original purchaser of a Fanimation Fan

1. LIMITED  LIFETIME  MOTOR  WARRANTY  -  If  any  part  of  your  fan  motor  fails,  due  to  a  defect  in  materials  or  workmanship

during the lifetime of the original purchaser, Fanimation will provide the replacement part free of charge, when the defective
fan  is  returned  to  our  national  service  center.  Proof  of  purchase  is  required.  Customer  shall  be  responsible  for  all  costs
incurred in the removal or reinstallation and shipping of the product for repairs or replacement.

2. ONE YEAR MOTOR LABOR WARRANTY - If your fan motor fails at any time within one year from the original purchase, due

to  defects  in  materials  or  workmanship,  labor  to  repair  the  motor  will  be  provided  free  of  charge  at  our  national  service
center.  Purchaser  will  be  responsible  for  labor  charges  after  this  one-year  period.  Customer  shall  be  responsible  for  all
costs incurred in the removal or reinstallation and shipping of the product for repairs or replacement.

3. If  any  other  part  of  your  fan  fails  at  any  time  within  one  year  after  original  purchase,  due  to  a  defect  in  materials  or

workmanship, we will repair, or replace, at our option, the defective part free of charge for parts and labor performed at our
national service center.

4. Because  of  varying  climate  conditions,  this  warranty  does  not  cover  changes  in  the  finish,  including  rusting,  pitting,

corroding, tarnishing, or peeling.

5. This  warranty  is  void  and  does  not  apply  to  damage  from  improper  installation,  neglect,  accident,  misuse,  exposure  to

extremes of heat or humidity, or as a result of any modification to the original product.

6. All  costs  of  removal  and  reinstallation  of  the  fan  are  the  sole  responsibility  of  the  owner  of  the  fan  and  not  the  store  that

sold the fan or Fanimation.

7. Fanimation  reserves  the  right  to  modify  or  discontinue  any  product  at  any  time  and  may  substitute  any  part  under  this

warranty.

8. Under no circumstances may a fan be returned without prior authorization from Fanimation. The receipt of purchase must

accompany  authorized  returns  and  must  be  sent  freight  prepaid  to  Fanimation.  The  fan  to  be  returned  must  be  properly
packed to avoid damage in transit; Fanimation will not be responsible for any damage resulting from improper packaging.

9. It  is  understood  that  any  repair  or  replacement  is  the  exclusive  remedy  available  from  Fanimation.  There  is  no  other

expressed  or  implied  warranty.  Fanimation  hereby  disclaims  any  and  all  implied  warranties,  including,  but  not  limited  to
those  of  merchantability  and  fitness  for  a  particular  purpose  to  the  extent  permitted  by  law.  Some  states  do  not  allow
limitations on implied warranties. Fanimation will not be liable for incidental, consequential, or special damages arising out
of or in conjunction with product use or performance, except as may otherwise be accorded by law. This warranty gives you
special legal rights and you may also have other rights that vary from state to state.

10. A certain amount of wobble is normal and should not be considered a problem or a defect.

Unpacking Instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Energy Efficient Use of Ceiling Fans . . . . . . . . . . . . . . . . . . . . .4
Electrical and Structural Requirements  . . . . . . . . . . . . . . . . . .4
How to Assemble Your Ceiling Fan . . . . . . . . . . . . . . . . . . . . . .5
How to Hang Your Ceiling Fan . . . . . . . . . . . . . . . . . . . . . . . . . .6
How to Wire Your Ceiling Fan  . . . . . . . . . . . . . . . . . . . . . . . . . .7
How to Install Your Canopy Housing  . . . . . . . . . . . . . . . . . . . .8

How to Assembly the Blades & Light Kit  . . . . . . . . . . . . . . . . .9
How to Operate Your Ceiling Fan  . . . . . . . . . . . . . . . . . . . . . .10
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
How to Clean Your Ceiling Fan Blades  . . . . . . . . . . . . . . . . . .11
Trouble Shooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Parts List and Exploded Illustration. . . . . . . . . . . . . . . . . . . . .13

Table of Contents

Содержание FP8050 The Quattro

Страница 1: ...Model No FP8050 Ceiling Fan OWNER S MANUAL READ AND SAVE THESE INSTRUCTIONS Net Weight 7 3 kgs 16 1 lbs The Quattro ...

Страница 2: ...he defective fan is returned to our national service center Proof of purchase is required Customer shall be responsible for all costs incurred in the removal or reinstallation and shipping of the product for repairs or replacement 2 ONE YEAR MOTOR LABOR WARRANTY If your fan motor fails at any time within one year from the original purchase due to defects in materials or workmanship labor to repair...

Страница 3: ...s product by Fanimation Substitution of parts or accessories not designated for use with this product by Fanimation could result in personal injury or property damage WARNING One wire stripper One 1 4 blade screwdriver Materials Wiring outlet box and box connectors must be of type required by the local code The minimum wire would be a 3 conductor 2 wire with ground of the following size NOTE Place...

Страница 4: ...ollar savings could be realized with this simple step Electrical and Structural Requirements If your fan is to replace an existing light fixture turn electricity off at the main fuse box at this time and remove the existing light fixture Your new ceiling fan will require a grounded electrical supply line of 120 volts AC 60 Hz 15 amp circuit The outlet box must be securely anchored and capable of w...

Страница 5: ...gure 3 4 Route wires through motor coupling cover canopy screw cover and canopy Figure 4 5 Reinstall the hanger ball on the downrod as follows Route the three 80 inch wires through the hanger ball Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball Pull the hanger ball up tight against the pin Securely t...

Страница 6: ...n for advise as it must be grounded for safe operation The outlet box must be securely anchored Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet box are not securely attached the fan could wobble or fall WARNING 2 Carefully lift the fan and seat the downrod hanger ball assembly on the hanger brack...

Страница 7: ...it into the open end of the hanger bracket Figure 4 4 Connect green wires from hanger bracket and hanger ball to bare ground wire using wire connector supplied Connect black wire from receiver unit marked AC IN L to black supply wire using wire connector supplied Connect white wire from receiver unit marked AC IN N to white supply wire using wire connector supplied Connect white wire from receiver...

Страница 8: ...de of the outlet box Figure 6 CANOPY SHOULDER SCREWS 2 Figure 1 CANOPY COVER Figure 2 1 Remove one of the two shoulder screws in the hanger bracket Loosen the second shoulder screw without fully removing it Assemble canopy by rotating key slot in canopy over shoulder screw in hanger bracket Tighten shoulder screw Fully assemble and tighten second shoulder screw that was previously removed Figure 1...

Страница 9: ...ector from the Upper Light Kit Plate to the 2 pin connector from motor assembly Figure 2 3 Assemble the Upper Light Kit Plate to the Housing Support Bracket by aligning key slots in Plate with the two screws in Support Bracket Assemble screw removed in step 2 and tighten all three screws Figure 3 Do not connect fan blades until the fan is completely installed Installing the fan with blades assembl...

Страница 10: ...y turning the electricity on at the main fuse box Figure 1 2 To make fan operational install 9 volt battery in hand held remote transmitter if not using for long periods of time remove battery to prevent damage to transmitter Store the remote away from excessive heat or humidly Figure 2 Check to see that all connections are tight including ground and that no bare wire is visible at the wire connec...

Страница 11: ...n Rotation Direction Switch Position Summer Counter Clockwise Left Winter Clockwise Right 5 BUTTON REMOTE CONTROL Figure 3 Maintenance 1 Periodic cleaning of your new ceiling fan is the only maintenance that is needed When cleaning use only a soft brush or lint free cloth to avoid scratching the finish Abrasive cleaning agents are not required and should be avoided to prevent damage to finish Do n...

Страница 12: ...s are not recommended choose an alternative control method 6 Tighten screws securely 7 Tighten set screw securely 1 Blades not attached to fan 2 Loose screws in motor housing 3 Screws securing fan blade holders to motor flywheel are loose 4 Wire connectors inside housing rattling 5 Motor noise caused by solid state variable speed control 6 Screws holding blades to blade holders are loose 7 Lower h...

Страница 13: ...y Loose Parts Wire Connector 4 Washer Head Screw 3 16 24 x 12 5mm 13 Fiber Washer 3 16 13 1 2 3 4 5 6 7 8 9 10 11 12 13 14 4 Phillips Head Screwdriver AMA8050 APGAC110RBL ADRAC1 45 P805001 APPAC1101 AP1115 AP805005 P805006CH PPGU10B50 AP805008 RECAN44 C24 BALKT HDWFP8050 Parts List 14 Insert FINISH CODE Refer to fan model number located on downrod support HOW TO ORDER REPAIR PARTS When ordering re...

Страница 14: ...Copyright Fanimation 2010 2010 05 10983 Bennett Parkway Zionsville IN 46077 Toll Free 888 567 2055 FAX 866 482 5215 Outside U S call 317 733 4113 Fanimation Visit Our Website www fanimation com ...

Отзывы: