Страница 1: ...OWNER S MANUAL READ AND SAVE THESE INSTRUCTIONS Model No TF300 The Edgewood Median Ceiling Fan Net Weight 7 67 kg 16 9 lbs...

Страница 2: ...may also have other rights that vary from state to state 10 A certain amount of wobble is normal and should not be considered a problem or a defect LIMITED LIFETIME WARRANTY Extends to the original pu...

Страница 3: ...crewdriver One wire stripper Four wire connectors supplied WARNING Do not install or use fan if any part is damaged or missing This product is designed to use only those parts supplied with this produ...

Страница 4: ...mmonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt Energy Efficient Use of Ceiling Fans Ceiling fan pe...

Страница 5: ...rough Motor Coupling Cover and Canopy Position Canopy on fan shown with open side facing up Figure 3 7 Reinstall the Hanger Ball Figure 3 on the Down rod as follows Route the three 80 wires through th...

Страница 6: ...g the 3 8 x 2 lag bolt and flat washer attach safety cable to ceiling joist or wood structural member The lag bolt will pass through the flat washer safety cable loop the junction box and into the bui...

Страница 7: ...n Wire Ground from Hanger Bracket Green Wire Ground Black Fan Wire White Blue Green Wire Ground from Hanger Bowl Figure 1 WARNING To avoid possible electrical shock be sure electricity is turned off a...

Страница 8: ...ith lock washers securing the Blade Holders to the Motor Hub are tight and that the Blade Holders are properly seated Figure 2 NOTE Periodically check Blade Holder hardware and re secure if necessary...

Страница 9: ...ssibility of electrical shock RECOMENDED Periodically check that the blade holders to motor hub screws are secure and tight 2 Assemble the Switch Cup Assembly onto the Housing Adapter with three screw...

Страница 10: ...d 2c Clevis Pin 2d Bridge Pin 3 Ceiling Canopy P30030 4 Motor Coupling Cover AP30050 5 Fan Motor Assembly MATF300 6 Switch Cup Assembly AP300010 7 Blade Holders Set of 5 AP30005 8 Blades Set of 5 AP30...

Страница 11: ...11 NOTE The illustration shown is not to scale or its actual configuration may vary TF300 Median Fan Exploded View Figure 1 2a 2b 2c 2d 2 3 4 5 7 1 6 8 9...

Страница 12: ...state controls are not recommended choose an alternative control method 6 Tighten screws securely 3 FAN WOBBLES EXCESSIVELY 1 Setscrew and nut in downrod support is loose 2 Setscrew in downrod hanger...