This Manual is Designed to Make it as Easy as Possible for You

to Assemble, Install, Operate, and Maintain Your Ceiling Fan

Unpacking Instructions

For your convenience, check-off each step.  As each step is completed, place a check mark.  This will ensure that all 
steps have been completed and will be helpful in 

fi

 nding your place should you be interrupted. 

Wiring outlet box and box connectors must be of type 

required by local code.  The minimum wire would be a 3-

conductor (2-wire with ground) of the following size:

NOTE:

  Place the parts from the loose parts bags in a small 

container to keep them from being lost.  If any parts are missing, 

contact your local retailer.

Tools Needed for Assembly

Materials

Wire Size A.W.G.

Installed Wire Length

14

12

Up to 50 ft.

50 - 100 ft.

NOTE:

  If you are uncertain of part description, refer to

exploded view illustration. (Figure 1, page 11)

3

1. 

Check to see that you have received the following 

parts: 

Blade Holders

Hardware Bag

Fan Motor

Assembly

Downrod/

Hanger Ball

Assembly

Ceiling Canopy

• One Phillips head screwdriver
• One stepladder
• One ¼

˝

 blade screwdriver

• One wire stripper

 

Four wire connectors

  (supplied)

WARNING

Do not install or use fan if any part is damaged or 

missing.  This product is designed to use only those 

parts supplied with this product and/or any accessories 

designated specifically for use with this product by 

Fanimation.  Substitution of parts or accessories not 

designated for use with this product by Fanimation could 

result in personal injury or property damage.  Contact 

your retail store for missing or damaged parts.

WARNING

Before assembling your ceiling fan, refer to section on 

proper method of wiring your fan (page 4).  If you feel you 

do not have enough wiring knowledge or experience, 

have your fan installed by a licensed electrician.

• Fan Motor Assembly

• Switch Cup Assembly

• Hanger Bracket

• Downrod/Hanger Ball

  Assembly

• Ceiling Canopy

• Motor Coupling Cover

• Blade Holder Arms (5)

• Blade (5)

• Hardware bag:

    – Eleven ¼

˝

-20 x ½

˝

       (blade holder to fan motor hub)

       screws with lockwashers

    – Sixteen 

3

/

16

-24 x 7.5mm (blade

       to blade holder) washer-head 

       screws with fiber washers

    – Two 5/32

˝

 threaded rods

    – Two 5/32

˝

 lockwashers

    – Two knurled knobs

    – Four wire connectors

    – Chain Coupler

    – Chain Fob

    – Balance Kit

    – Ceiling Support Cable

       with Clamp

    – 

3

/

8

˝

 x 2

˝

 Lag Bolt

    – Flat Washer

Hanger Bracket

Blade Set

Switch Cup

Assembly

Motor Coupling 

Cover

Содержание Edgewood TF300 Series

Страница 1: ...OWNER S MANUAL READ AND SAVE THESE INSTRUCTIONS Model No TF300 The Edgewood Median Ceiling Fan Net Weight 7 67 kg 16 9 lbs...

Страница 2: ...may also have other rights that vary from state to state 10 A certain amount of wobble is normal and should not be considered a problem or a defect LIMITED LIFETIME WARRANTY Extends to the original pu...

Страница 3: ...crewdriver One wire stripper Four wire connectors supplied WARNING Do not install or use fan if any part is damaged or missing This product is designed to use only those parts supplied with this produ...

Страница 4: ...mmonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt Energy Efficient Use of Ceiling Fans Ceiling fan pe...

Страница 5: ...rough Motor Coupling Cover and Canopy Position Canopy on fan shown with open side facing up Figure 3 7 Reinstall the Hanger Ball Figure 3 on the Down rod as follows Route the three 80 wires through th...

Страница 6: ...g the 3 8 x 2 lag bolt and flat washer attach safety cable to ceiling joist or wood structural member The lag bolt will pass through the flat washer safety cable loop the junction box and into the bui...

Страница 7: ...n Wire Ground from Hanger Bracket Green Wire Ground Black Fan Wire White Blue Green Wire Ground from Hanger Bowl Figure 1 WARNING To avoid possible electrical shock be sure electricity is turned off a...

Страница 8: ...ith lock washers securing the Blade Holders to the Motor Hub are tight and that the Blade Holders are properly seated Figure 2 NOTE Periodically check Blade Holder hardware and re secure if necessary...

Страница 9: ...ssibility of electrical shock RECOMENDED Periodically check that the blade holders to motor hub screws are secure and tight 2 Assemble the Switch Cup Assembly onto the Housing Adapter with three screw...

Страница 10: ...d 2c Clevis Pin 2d Bridge Pin 3 Ceiling Canopy P30030 4 Motor Coupling Cover AP30050 5 Fan Motor Assembly MATF300 6 Switch Cup Assembly AP300010 7 Blade Holders Set of 5 AP30005 8 Blades Set of 5 AP30...

Страница 11: ...11 NOTE The illustration shown is not to scale or its actual configuration may vary TF300 Median Fan Exploded View Figure 1 2a 2b 2c 2d 2 3 4 5 7 1 6 8 9...

Страница 12: ...state controls are not recommended choose an alternative control method 6 Tighten screws securely 3 FAN WOBBLES EXCESSIVELY 1 Setscrew and nut in downrod support is loose 2 Setscrew in downrod hanger...

Страница 13: ......

Страница 14: ...Copyright 2007 Fanimation 2007 02 10983 Bennett Parkway Zionsville IN 46077 888 567 2055 FAX 866 482 5215 Outside U S call 317 733 4113 Visit Our Website www fanimation com...