OPERATING FEATURES and INSTRUCTIONS (Cont.) 

 

Keypad Buttons and Their Functions 
 

ON-OFF: 

The ON-OFF button is located in the upper right corner of the DFM 
module. 

 

Pressing the ON-OFF button while the air sampler is connected to line 
power but not running will place the unit in standby mode. Power is 
enabled to the DFM. 

 

RESET: 

The RESET button is located in the lower right hand corner of the DFM 
module. 

 

The RESET button is utilized to start and stop the air sampler motor, to 
commence a sampling event or to terminate a sampling event, when 
manual on/off is enabled. 

Note: 

The DFM must be in flow mode for Reset to function as a pump 

On-Off button. 

 

The accumulated elapsed time and accumulated total volume are not 
automatically reset to zero when the air sampler is started. This feature 
allows the operator to temporarily suspend sampling for maintenance, to 
implement a different set up, or to enable different features. 

 

Note: 

In Time display mode, the RESET button zeros the elapsed time.  

In Total Volume display mode, the RESET button zeros total volume. 

 

UNITS:

 

The UNITS button is located on the right side of the DFM module.  
Pressing the UNITS button enables an operator to display flow, elapsed 
time, or total volume by advancing the green LED to the different 
positions.

 

 
 
 
 
 
 
 
 
 

The default position of the green LED is the Flow position upon start up or return to power after a 
power outage.

 

 

Pressing the UNITS button once moves to the Elapsed Time (

time

) position displayed 

in HHH:MM (Hours-Minutes mode). 
Pressing the UNITS button when the green LED is in the 

time

 position advances to the 

total volume 

position. 

NOTE:

 Do not assume that total volume and elapsed time are zero when flow is zero.  

Check both the elapsed time and total volume values prior to commencing a sample 
event. 

 

Содержание DF-75L-Li

Страница 1: ...ir Samplers DF Battery TECH MANUALS DF 75 LPM SERIES doc F J SPECIALTY PRODUCTS INC The Nucleus of Quality Air Monitoring Programs EMERGENCY RESPONSE AIR SAMPLING SYSTEM Digital Flowmeter Technology 7...

Страница 2: ...ence T and P Low Voltage Limiting System Description 22 Calibration Instructions 23 25 Maintenance Instructions 26 Spare Parts List 27 28 Electrical Wiring Diagrams 29 30 Warranty Information and Limi...

Страница 3: ...s not available The automatic flow control feature with the F J Digital Flowmeter technology provides maximum flexibility for emergency response sampling responsibilities The set flowrate is maintaine...

Страница 4: ...Weight 15 3 lbs 7 kg Dimensions 8 9 12 20 23 30 cm Display Bright LED 6 character 1 2 cm H Elapsed Time DD HH MM up to 168 hours Flow Control Adjustable from keypad between 30 75 LPM Flow Accuracy 4...

Страница 5: ...e applications when line power is not available The unit may be operated from solar power or wind power source through either the AC input or DC input The automatic flow control feature with the F J D...

Страница 6: ...racter 1 2 cm H Elapsed Time DD HH MM up to 168 hours Flow Control Adjustable from keypad between 30 75 LPM Flow Accuracy 4 0 of Full Scale Factory Settable Reference T and P Classical STP 0 C 1 ATM N...

Страница 7: ...he user or maintenance personnel to proceed with caution When you see this symbol be aware that personal injury or property damage is possible The hazard is explained in text following the symbol Read...

Страница 8: ...er into the local line power using the power cord provided after confirmation of line power compatibility in step 3 above If a local style plug is required install the plug in accordance with local el...

Страница 9: ...e 75 LPM DF Battery Series air samplers have all the operational components conveniently accessible to the user Model DF 75L AC and DF 75L Li air sampler s pertinent components are illustrated below i...

Страница 10: ...OW MEASUREMENT Flow is indicated on the LED display when the UNITS green LED is in the FLOW position on the DFM Various flowmeter ranges and flow measurement units are selectable at the time of purcha...

Страница 11: ...air sampler Through the DFM the operator activates the features of the instrument as well as monitor the flow parameters The keypad for the DFM series of air samplers has the following features 1 Four...

Страница 12: ...ot automatically reset to zero when the air sampler is started This feature allows the operator to temporarily suspend sampling for maintenance to implement a different set up or to enable different f...

Страница 13: ...The SET button is utilized to set enable or disable one or more of the available features listed below Automatic Shut Off on time Automatic Shut Off on volume Activation of Flow Control Selection of D...

Страница 14: ...to 99999 or in x xxxEyyy format for larger numbers This format ensures the possible best resolution even for large values Ambient flow has an a as prefix ccccccccc corrected flow same format as for t...

Страница 15: ...m Hg NOTE F J does not recommend the installation of the Actual Flow options for sampling activities of more than 8 hours in duration or if sample volumes or resultant data are to be compared between...

Страница 16: ...ress the SET button to move to the hours set up screen Press the UNITS button to increase the hours value or the RESET button to decrease the hours value NOTE If the hours value has changed pressing t...

Страница 17: ...requency Feature SIO 1S 1m 6m or 1hr appears on the display Press the UNITS or RESET button to change the frequency at which data is to be sent to a data storage device Press the SET button to advance...

Страница 18: ...sition 4 If the motor is not running press the RESET button to start the sample event Temporary Suspension of an Air Sample Event 1 Ensure that the UNITS LED is in the Flow position then PRESS the RES...

Страница 19: ...sis Extra filter holders may be purchased separately F J plastic filter holders available for the Low Volume Series Air Sampler are listed below MODEL DESCRIPTION FJ 05P Open face plastic combination...

Страница 20: ...ensor measures the differential pressure across the flow sensor The total system accuracy of the digital flowmeter air sampler flow sensor and the differential sensor electronics is accurate to 4 The...

Страница 21: ...phere pressure is the default reference pressure The equation utilized to correct the flow at field conditions to a reference T and P is as follows Flow REF Flow Actual T REF P ACTUAL T ACT 29 92 Hg 7...

Страница 22: ...e and increases the number of charging cycles This low voltage limiting circuitry is factory preset Once the battery voltage reaches the factory preset level the instrument will shut down and go into...

Страница 23: ...libration verification procedure involves the comparison of the flow value displayed on the Digital Flowmeter Air Samplers to the flow value displayed on the reference calibrator The filter media to b...

Страница 24: ...the same engineering units that the air sampler is reading CFM or LPM Confirm that the filter paper is installed and that there isn t air leakage in the system 3 Start the air sampler and adjust to s...

Страница 25: ...____________ ____________ _________ Flow Rate 4 ______________ _________________ ____________ _________ Record reference values 2 and Air Sampler values 1 in same units Deviation 3 Reference Calibrato...

Страница 26: ...instrument 5 Disconnect all the electric and sensor connections to the DFM and Battery Gauge Indicator Refer to the spare parts list and electrical diagram on the following pages These connections ar...

Страница 27: ...60Hz 220 240VAC 50 60Hz LIP 18650 Lithium ion Battery 15 6 Ah LIP 18650 F3AMP Fuse 3 Amp F3AMP 310005 12 VDC Motor 60 Watts 310005 310006 18 VDC Motor 60 Watts 310006 AN37105 AC Power Cord AN37106 CEI...

Страница 28: ...38 Intake Port Hose Barb ELECTRICAL PARTS Part Number Description Part Number 110 120VAC 50 60Hz 220 240VAC 50 60Hz F3AMP Fuse 3 Amp F3AMP 310005 12 VDC Motor 60 Watts 310005 310006 18 VDC Motor 60 Wa...

Страница 29: ...F MARKETING TECHNICAL MANUALS Air Samplers DF Battery TECH MANUALS DF 75 LPM SERIES doc Tel 352 680 1177 Fax 352 680 1454 Email fandj fjspecialty com 29 ELECTRICAL WIRING DIAGRAM for DF 75L Li...

Страница 30: ...F MARKETING TECHNICAL MANUALS Air Samplers DF Battery TECH MANUALS DF 75 LPM SERIES doc Tel 352 680 1177 Fax 352 680 1454 Email fandj fjspecialty com 30 ELECTRICAL WIRING DIAGRAM for DF 75L AC...

Страница 31: ...effective only if installation use and maintenance is in accordance with Seller s instructions and written notice of a defect is received by the Seller within the period herein provided Seller shall...

Страница 32: ...expedite service and repairs have your Business Name and or Customer Number handy Please ensure that all products returned to F J contain no hazardous materials Any obviously contaminated product rec...

Страница 33: ...75 LPM SERIES doc Tel 352 680 1177 Fax 352 680 1454 Email fandj fjspecialty com 33 Fast Friendly Customer Service Ordering by phone 352 680 1177 680 1178 Ordering by Fax 352 680 1454 For your convenie...

Отзывы: