Purpose

Functioning

The roller blind controller STR-2 is designed for controlling roller blinds 
(up and down movement) or other devices (for example, gates) that 
are driven by a single-phase AC electric motor and operated by means 
of momentary switches (for example, bell-pushes). The controller can 
operate as an independent unit (designated for opening/closing one 
roller blind) as well as the controllers can be combined into groups that 
enable the central controlling of many roller blinds

Supplied the relay is to sigal by shine of green LED U. The roller blind 
motor is activated by the momentary switching of a current pulse (L or 
N)  to  one  of  the  control  inputs.  The  motor  is  activated  at  a  time 
programmed previously by the user. The activation time programmed 
enables the complete lifting or lowering of the roller blind. Also, there 
is a possibility of stopping the rolled blind activated at a level selected 
by the user (non-complete opening or closing of the roller blind).

Control inputs of relay:

Local control

  - buttons connected to contact 6 and  control one roller 

blind 

-upwards (opening);  - downwards (closing).

Pressing the local control push-button activates the movement of the 
roller blind in a selected direction. If the roller blind is already moving, 
pressing the local control push-button will stop the roller blind.

Central control

 - a common group of push-buttons which are connect 

to contact 7 and 8 for many controllers (minimum two controllers) that 
controls all roller blinds included in the central control system

   - all upwards;      - all downwards.

Pressing the central control push-button activates the movement of 
the roller blinds in a selected direction. If one of the roller blinds is 
already moving in the same direction, its movement will be continued. 
If one of the roller blinds is moving in the opposite direction, this roller 
blind will be first stopped and then its movement will be activated in 
the  direction  in  accordance  with  the  command  sent  to  the  central 
input.

ATTENTION!

 The central control enables only activating the movement 

of  the  roller  blinds  in  a  selected  direction.  The  roller  blind  will  be 
stopped after the programmed movement time or when any of the 
local control push-buttons is pressed.

Ź



ŹŹ



Wiring diagram

LOCAL

CONTROL

CENTRAL
CONTROL

LOCAL

CONTROL

STR

STR

Description of connection:

1 - 2

supply 230V (L - N)

3

supply of motor - output in to direction „UPWARDS” 

4

supply of motor - output in to direction „DOWNWARDS” 

6

local control  - to direction „DOWNWARDS/UPWARDS”

 

local control  - to direction „UPWARDS” 

8

local control  - to direction „DAWNWARDS”

 

”?

““

””

Control  inputs  could  be  supplied  from  a  phase  cable  (L)  or 
neutral cable (N). Make a choose of one control option for all 
inputs.

Ex

ample of wiring diagr

am f

or ins

talla

tion with tw

o r

oller blind c

on

tr

oller 

which w

ork in c

ommon cen

tr

al c

on

tr

ol (c

on

tr

ol signal: N) 

1

2

3

4

6

7

8

M

L

N

L/N

L/N L/N

M

M

L

N

CENTRAL

CONTROL

4

6

7

8

3

1

2

4

6

7

8

3

1

2

F&F Filipowski sp. j.

Konstantynowska 79/81   95-200 Pabianice   

phone/fax: (+48 42) 215 23 83 / 227 09 71    POLAND

http://www.fif.com.pl   e-mail: [email protected]

WARRANTY.

  The  F&F  products  are 

covered by a warranty of the 24 months   
from the date of purchase.  Effective only 
with  proof  of  purchase.  Contact  your 
dealer or directly with us. More informa-
tion  how  to  make  a  compliant  can  be 
found on the website:
www.fif.com.pl/reklamacje

ROLLER BLIND CONTROLLER

one-button type

Do not dispose of this device in the trash along with other waste! 

According 

to the Law on Waste, electro coming from households free of charge and can 
give any amount to up to that end point of collection, as well as to store the 
occasion of the purchase of new equipment (in accordance with the principle 
of old-for-new, regardless of brand). Electro thrown in the trash or abandoned 
in nature, pose a threat to the environment and human health.

STR-2

5

9 0 8 3 1 2

5 9 3 3 2 4

- 3 -

- 4 -

- 2 -

Отзывы: