- 2 -

B

B. Bistable relay with step automatic module.

 A single pressing 

of the START button results in activating the relay for the preset 

time. A further START impulse generated during the countdown 

will deactivate the relay. Two START impulses applied within a 

time shorter than 1 sec will result in the permanent activation of 

the relay. The following impulse turns the relay OFF.

C

C. Generator with a pulse duty factor of 50%

 which initiates it’s 

working sequence from the moment of activation. It is active as 

long as START voltage is applied. Once the START signal is discon-

nected, the connection is broken and the device is deactivated.

D

Содержание PCS-506

Страница 1: ...elay off The device does not respond to time range settings Purpose Operating F F Filipowski sp j Konstantynowska 79 81 95 200 Pabianice POLAND phone fax 48 42 215 23 83 48 42 227 09 71 www fif com pl e mail biuro fif com pl Donotdisposeofthisdeviceinthetrashalongwithotherwaste According to the Law on Waste electro coming from households free of charge and can give any amount to up to that end poi...

Страница 2: ...elay Two START impulses applied within a time shorter than 1 sec will result in the permanent activation of the relay The following impulse turns the relay OFF C C Generator with a pulse duty factor of 50 which initiates it s working sequence from the moment of activation It is active as long as START voltage is applied Once the START signal is discon nected the connection is broken and the device...

Страница 3: ...railing edge of the reset signal and the leading edge of the START signal which re initiates the countdown sequence should be at least 0 5 sec E E Generation of a single impulse of t time by the START si gnal up trailing edge During preset time countdown the system does not respond to START impulses F F Generation of a single impulse of t time by the START signal down trailing edge During preset t...

Страница 4: ...upport function ena bled If the START voltage is supplied for less than 45 sec it is ignored by the system however if it is longer the relay is activa ted after the 45 sec and the preset time value is counted down with the trailing edge of the START signal If another START im pulse is applied during the countdown then the trailing edge of this signal will result in the repeated countdown sequence ...

Страница 5: ... t for example 1 m 7 7 min The black box in the diagram shows the position of the switch 5 4 6 OFF 5 0 1 s 4 6 1 s 5 4 6 10 s 5 4 6 1 min 5 4 6 ON 5 4 6 2 h 5 4 6 10 min 5 4 6 Time ranges The required time range and the working mode of the relay is selected by choosing the proper combination of the switches black field in the diagram stands for the switch position A E 3 B F C G D H 2 1 3 2 1 3 2 1...

Страница 6: ...r the power supply is switched off and back on With the power supply on it is possible to regulate the preset time freely within the selected time range 0 1s 0 1 1 2sec 10m 10 120min 1s 1 12sec 2h 2 24 h 10s 10 120sec 1d 1 12days 24 288h 1m 1 12min 2d 2 24days 48 576h ON position with power supply activated causes the contact to be permanently opened OFF position with power supply activated causes...

Страница 7: ...e one of control impulse option L or N Control buttons connected in parallel connect between the red wire and the wire of the selected control signal option L or N 5 Connect the controlled receiver to the black wire and the neu tral wire N 6 By code switches set work function and time range 7 By knob set time work Mounting Wiring diagram ...

Страница 8: ... covered by a warranty of the 24 months from the date of purchase Effective only with proof of purchase Contact your dealer or directly with us F F Filipowski sp j declares that the device is in conformity with the essential requirements of The Low Voltage Directive LVD 2014 35 EU and the Electromagnetic Compatibility EMC Directive 2014 30 UE The CE Declaration of Conformity along with the referen...

Отзывы: