power supply 

195÷265 V AC

maximum load current (AC-1) 

10 A

twilight activation threshold 

3÷2000 lx

motion detection 

0.6÷1.5 m/s

switch-off time 

3 s÷9 min. (±2min.)

horizontal detection area 

360°

max radius of detection (T<24°C) 

10 m

sensor mounting height 

2.2÷6 m

power consumption

standby 

0.10 W

on 

0.45 W

terminal 

1.5 mm² screw terminals

tightening torque 

0.3 Nm

working temperature 

-20÷40°C

dimensions 

102×102 mm, h= 55 mm

mounting surface

ingress protection 

IP65

Technical data

Содержание DR-09-IP65

Страница 1: ...the sensor detects continuous movement Only if there is no movement in the detection area triggers the lighting support time Another movement in the detection area and its subsequ ent disappearance in the course of time measurement starts the support time from the beginning Purpose Functioning F F Filipowski sp j Konstantynowska 79 81 95 200 Pabianice POLAND phone fax 48 42 215 23 83 48 42 227 09 ...

Страница 2: ...The activation time of the sensor can be adjusted by the user using a potentiometer In addition it is possible to adjust the time of sensor switching on within the range of 3 s 9 min Changes in temperature can affect the motion detec tion The minimum distance between the sensor and the li ght source is 60 cm If the motion sensor is installed too close to the switched light source the system may be...

Страница 3: ...e sensitivity of the twilight sensor can be adjusted within the range of 3 lx to 2000 lx Turning the control knob in the direction of the moon icon will switch the light later turning it in the direction of the sun will switch the light earlier For the sensor to be active throughout the whole day the control knob should be maximally turned in the direction of the sun Sensor installation height adj...

Страница 4: ... 4 The direction of movement in the detection area Dimensions ...

Страница 5: ...he motion sensor is installed too close to the switched light source the system may be activated which means that the sensor will automatically switch on and off the light source It is necessary to move the sensor to an ap propriate distance away from the light source The sensor is inactive for the first 30 seconds after the power supply is switched on During this time the PIR system warms up The ...

Страница 6: ...locations with large objects in the detection area such as trees that can be moved by the wind Do not install the sensor in the immediate vicinity of he ating air conditioning and lighting devices Wiring diagram ...

Страница 7: ...h off time 3 s 9 min 2min horizontal detection area 360 max radius of detection T 24 C 10 m sensor mounting height 2 2 6 m power consumption standby 0 10 W on 0 45 W terminal 1 5 mm screw terminals tightening torque 0 3 Nm working temperature 20 40 C dimensions 102 102 mm h 55 mm mounting surface ingress protection IP65 Technical data ...

Страница 8: ... F F products are covered by a warranty of the 24 months from the date of purchase Effective only with proof of purchase Contact your dealer or directly with us F F Filipowski sp j declares that the device is in conformity with the essential requirements of The Low Voltage Directive LVD 2014 35 EU and the Electromagnetic Compatibility EMC Directive 2014 30 UE The CE Declaration of Conformity along...