2. Technical specifications
2
2.
Technical specifications
Power supply
Mains voltage
230Vac (-10% +6%)
or 115Vac (-10% +6%)
by power supply selection
Mains frequency
50-60Hz
Power consumption ( of VLR.6)
3.5VA
Max. current output
6A
Fuse (dimensions 6.3×32mm)
Very Fast Acting 10A - 250V
Power outage relay
Relay de-energizes if the power fails
30Vac/60Vdc - max. 2A
Control
Type
10-0Vdc/0-10Vdc
Input resistance
120k
Ω
Manual operation
Knob
for 0-100% if the 10-0Vdc control fails
Switch
for “man-0-aut” (man = directly on mains)
Housing
Plastic housing with screw on lid
IP54
Dimensions (l×w×h)
180×240×140 (7.1×9.4×5.5 inches)
Weight (unpacked)
1.9kg(4.2lbs)
Ambient climate
Operating temperature range
0
°
C to +40
°
C (32
°
F to104
°
F)
Storage temperature range
-10
°
C to 50
°
C (14
°
F to 112
°
F)
Relative humidity
< 95%, uncondensed
!
Fancom advises 2-wire connection of Fancom fans. If the fans are
connected parallel, heat production per fan may increase (causing
a shortened working life). Fancom therefore advises not to parallel
switch more than three fans. See connection diagrams.