FaroTek
Connecting the parts of the FaroTek system
14
3
Extension bus cable to the next
dispenser
Minus (green)
Data + (white)
Data
– (brown)
+24V (yellow)
4
Cable of the push sensor
blue
black
brown
Connect the FaroTek dispenser as follows:
1.
Connect the cable of the push sensor (4)
2.
Connect the FaroTek dispensers to their corresponding FaroTek power pack
Route the cable PIONET LIYCY (TP) 2X2X0,75 MM2 from the FaroTek power pack into the first FaroTek
dispenser (2). If there are other FaroTek dispensers to be connected to this FaroTek power pack, then route
a bus cable from this FaroTek dispenser (3) to the next one until all FaroTek dispensers of this FaroTek
power pack are connected to a bus cable (max. 8 FaroTek dispensers per FaroTek power pack!).
The cable between a FaroTek power pack and the last connected FaroTek dispenser should not
exceed 50 meter.
3.
Protect the dispenser motor housing
Close the cover of the motor housing and make sure that the gasket as well as the cable glands are properly
positioned to prevent dirt and moisture from entering the motor housing.
Содержание FaroTek