7
Input voltage of 24V DC:
24V DC
Copper section mm2
(25 W/h, I=1,042,08)
Cable
length (m)
(both ways)
minimum
(PT 5%)
maximum
(PT 2.5%)
Rigid
wire’s
cross-section
AWG equivalence
1
0.01
0.03
0,5 mm2
AWG 20
2
0.03
0.06
0,5 mm2
AWG 20
5
0.07
0.15
0,5 mm2
AWG 20
10
0.15
0.30
0,5 mm2
AWG 20
15
0.22
0.44
0,5 mm2
AWG 20
20
0.30
0.59
0,75 mm2
AWG 18
25
0.37
0.74
0,75 mm2
AWG 18
30
0.44
0.89
1 mm2
AWG 18
8.2.2 How to install Back Casings Wall
8.2.2.1 Tools of the installer
8.2.2.1.1 Tools list
The installer should be equipped with the following tools:
Designation
Quantity
Drill
1
Electric screwdriver (optional)
1
Torx screwdriver TT20, shaft length 80 mm
1 per installer
8.2.2.1.2 List of supplies
Designation
Comment
Quantity
Drill between 5 and 8 mm, depending on
type of anchorage desired
Drilling for fixing screws
1
Electric cable
Power cables, section and length
depending on the voltage and the
location of the power plug (*)
2
(*) refer to chapter "Electrical recommendations"